4. Pump stops working, wait for 10 seconds.
5. Pump runs a third time for approx. 40 seconds.
(at this time, if the water is back to normal, the controller will be back to normal working status)
6. Pump stops working and enters into the state of water shortage protection.
After 24 hours, the controller will start again this detection cycle under shortage water process.
Adjusting the pressure
When you need to adjust the pressure, remove the top cover (2).
[a] Use screwdriver to remove screws from top cover.
[b] Use a screwdriver to adjust the regulating screw:
- Turn clockwise to increase the pressure
- Turn counterclockwise to reduce the pressure
The factory pressure setting is 1.5bar.
VI. MAINTENANCE AND STORAGE
Before any intervention on product, ensure that product is disconnected form its
power source.
6.1- Maintenance
Clean plastic parts with a soft clean cloth.
Do not use aggressive cleansers (solvents or abrasive cleansers), or an abrasive sponge.
Do not put or immerse product in water or any other liquid.
6.2- Storage
Product must be stored in a dry location. Always lock up product and keep out of reach of children
6.3- Discarding
When discarding the pump, do not dispose of with household rubbish; do not discard in the environment.
Discard product in a dumping centre or collection centre or seek advice from your local authority.
Proceed with the disposal of the product, accessories and packaging in accordance with local legislation
related to environment protection
[a]
[b]
Page 15 / 23