Event Logs
51 01
1. Intruder Alarm
51 02
2. Panic Alarm
51 03
3. Fire Alarm
51 04
4. Duress Alarm
51 05
5. Sabotage Alarm
51 06
6. Medical Alarm
51 07
7. Duress Disarm
51 08
8. Disarm on Alarm
51 09
9. Zone Trouble
51 10
10. AC Fail
51 11
11. Intrusion Verifier
51 12
12. Cross Zone Fault
51 13
13. Battery Low
51 14
14. Line Fail
51 15
15. Battery Fail
51 16
16.Communic. Fail (1)
51 17
17.Special Arm/Disarm
51 18
18. Arm/Disarm
51 19
19. Bypassed
51 20
20. Entered Program
51 21
21. Exited Program
51 22
22. Periodic Report
51 23
23. Panel Restarted
51 24
24. Manual Report
51 25
25. ---
51 26
26. ---
51 27
27. ---
51 28
28. ---
51 29
29. ---
51 30
30. Custom Zone Alarm
51 31
31. ---
51 32
32. Defaults Loaded
33-64. Restore (2)
Contact ID
Event Logs
1. Intruder Alarm
52 01
2. Panic Alarm
52 02
3. Fire Alarm
52 03
4. Duress Alarm
52 04
5. Sabotage Alarm
52 05
6. Medical Alarm
52 06
7. Duress Disarm
52 07
8. Disarm on Alarm
52 08
9. Zone Trouble
52 09
10. AC Fail
52 10
11. Intrusion Verifier
52 11
12. Cross Zone Fault
52 12
13. Battery Low
52 13
14. Line Fail
52 14
15. Battery Fail
52 15
16.Communic. Fail (1)
52 16
17.Special Arm/Disarm(2)
52 17
18. Arm/Disarm
52 18
19. Bypassed
52 19
20. Entered Program
52 20
21. Exited Program
52 21
22. Periodic Report
52 22
23. Panel Restarted
52 23
24. Manual Report
52 24
25. ---
52 25
26. ---
52 26
27. ---
52 27
28. ---
52 28
29. ---
52 29
30. Custom Zone Alarm
52 30
31. ---
52 31
32. Defaults Loaded
52 32
33-64. Restore (3)
ADDRESS
FUNCTION
TD-1/07-008
1. option= Call Central Monitoring Station
2. option= Call User Phone
3. option= Call Central Monitoring Station for Restore
4. option= Call User Phone for Restore
5. option= Record to Memory
(1) Communication Fail is only recorded to Memory
(2) Restores no 3364 is displayed in event log memory if
event is selected to be recorded to memory.
CCCC 4 digits Event Code
Note:
(1) Communication Fail is only recorded to
Memory.
(2) Special Arm/Disarm codes sent to Central
Monitoring Station on Quick Arm, Arming on no
activity, Automatic Arm/Disarm, Arm/Disarm by
key, Arm/Disarm by Remote Controller
(3) Restores no 3364 is displayed in event log memory if
event is selected to be recorded to memory.
VALUE
1,2,3,5
1,2,3,5
1,2,3,5
1,2,3,5
1,2,3,5
1,2,3,5
1,2,5
1,5
1,5
1,3,5
1,5
1,5
1,3,5
1,3,5
68
1,3,5
IP
69
5
70
1,3,5
1,3,5
1,3,5
1,5
1,5
1
5
---
---
---
---
---
---
1,2,5
---
5
1130
1120
1110
1120
1144
1100
1121
1406
1372
1301
1139
1378
1302
1351
1302
71
0000
IP
1400
72
1402
1570
1627
1628
1602
1305
1601
0000
0000
0000
0000
0000
0000
0000
0000
PAGE &
DEFAULT
ENTERED
PROGRAM
VALUE
VALUE
IP:Installer
MP:Master
24/83