15 02
Answer Ring Count
16 01
KEY Settings
16 02
KEY Partitions
Zone Wiring
20 01
Z1
20 02
Z2
20 03
Z3
20 04
Z4
20 05-08
Z5-Z8
Zone Partitions
21 01
Z1
21 02
Z2
21 03
Z3
21 04
Z4
21 05-08
Z5-Z8
Zone Type
22 01
Z1
22 02
Z2
22 03
Z3
22 04
Z4
22 05-08
Z5-Z8
Zone Extra Settings
23 01
Z1
23 02
Z2
23 03
Z3
23 04
Z4
23 05-08
Z5-Z8
FUNCTION
ADDRESS
Zone Trigger Delay
24 01
Z1
24 02
Z2
24 03
Z3
24 04
Z4
24 05-08
Z5-Z8
Keypad Permissions
30 01
1. Keypad
30 02
2. Keypad
30 03
3. Keypad
30 04
4. Keypad
Keypad Partitions
31 01
1. Keypad
31 02
2. Keypad
31 03
3. Keypad
31 04
4. Keypad
TD-1/07-008
1~20 times
1. option= Enable(ON)/ Disable(OFF)
2. option= Pulse/ Continues Contact
1. option= A Partition
2. option= B Partition
3. option= C Partition
4. option= D Partition
1. option= NC/NO (ON/OFF)
2. option= Single end of line resistor,
Double zone ON/OFF *
3. option= Double end of line Resistor,
Double zoneON/OFF *
4. option= Zone Enable/Disable
(*)2, 3 must not be selected if no end of line resistor
will be used.
2, 3 must be selected in zone doubling.
You don't need to activate zone doubling feature
of Z5, Z6, Z7, Z8 while using zone doubling.
Zone doubling feature can't be used together
with zone expansion module.
1. option= A Partition Note: If S.P.T. (Smart partition
2. option= B Partition Technology) is selected,
3. option= C Partition
these settings can be
4. option= D Partition ignored.
0 = Free
6 = Fire
1 = Door
7 = Panic
2 = Window
8 = Duress
3 = Interior
9 = Tamper(Sabotage)
4 = Exterior
10 = Medical
5 = 24 Hour
11 = Custom
(ON/OFF)
1. option= End door YES/NO
2. option= Follower Zone YES/NO
3. option= Entry/Exit Zone YES/NO
4. option= Silent Zone YES/NO
5. option= Can not be bypassed manually YES/NO
6. option= Can not be Auto bypassed YES/NO
7. option= Cross Zone YES/NO
VALUE
2~255, time = value*30 ms
1. option= Keypad Enable/Disable
2. option= Quick Arm Enable/Disable
3. option= Arm Enable/Disable
4. option= Disarm Enable/Disable
5. option= Programming permission Enable/Disable
6. option= Access Control ON/OFF
7.option= Sabotage Alarm Enable/Disable
1. option= A Partition
2. option= B Partition
3. option= C Partition
4. option= D Partition
53
5 times
IP, MP
Closed,
53, 54
Pulse
54
IP
A,B,C,D
Look at pg.
34 for SPT
54
IP
1= ON
55
4= ON
55
IP
A
Look at pg.
34 for SPT
Z1:1
Z2:3
56
IP
Z3:3
Z4:3
Z5-Z8 : 3
Z1: 3
Z2: 2
57
IP
Z3: -
Z4: -
Z5-Z8: -
PAGE &
DEFAULT
PROGRAM
ENTERED
VALUE
IP:Installer
VALUE
MP:Master
58
15
IP
1.keypad
1,2,3,4,5
58
Other
IP
keypads
2,3,4
59
IP
A,B,C,D
Look at pg.
34 for SPT
21/83
IP