Festo DAPZ−SB−M−250AC−DR−AR Notice D'utilisation page 38

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 58
DAPZ−...−AR
Sensor
Function
Switching element
function
Rated switching capa
city
Minimum switching ca
pacity
Nominal voltage
Operating voltage
Operating current
Current consumption
Sensor attenuated
Sensor not attenu
ated
Insulation voltage
Surge Capacity
Degree of contamina
tion
Electrical limits of sen
sor circuit
Protection class
Based on the standard
*) The product may only be used in the same type of circuit during the complete period of
use.
38
DAPZ−SB−
DAPZ−SB−
M−250AC−DR−AR
I−30DC−DR−AR
Micro switch *)
Inductive
Changeover switch
PNP normally−
open contact
100 mA
at 250 V AC
1 mA at 4 V DC
4 ... 250 V AC/DC
10 ... 30 V DC
1 ... 5000 mA
0 ... 100 mA
250 V
50 V
2.5 kV
0.5 kV
3
IP67 to EN 60529
EN 60947−5−1
EN 60947−5−2
DAPZ−SB−
I−25DC−EXDR−AR
Inductive
Namur normally−
closed contact
8 V DC
1 mA
3 mA
50 V
0.5 kV
Ui = 16 V
Pi = 34 mW
Ii = 25 mA
EN 60947−5−2
Festo DAPZ−...−AR 0711b English

Publicité

Table des Matières
loading

Table des Matières