Télécharger Imprimer la page

Hansgrohe Talis S 06453 0 Serie Instructions De Montage page 2

Masquer les pouces Voir aussi pour Talis S 06453 0 Serie:

Publicité

English
Technical Information
Recommended water pressure
Max. water pressure
Recommended hot water temp. 120° - 140° F*
Max. hot water temp
Flow rate @ 44 PSI
Hole size in mounting surface
Max. depth of mounting surface
*Please know and follow all applicable local plumbing
codes when setting the temperature on the water heater.
Installation Considerations
• For best results, Hansgrohe recommends that
this unit be installed by a licensed, profes-
sional plumber.
• Please read over these instructions thoroughly
before beginning installation. Make sure that
you have all tools and supplies needed to
complete the installation.
• The mounting surface must be completed and
made watertight before installing this valve.
• This valve requires ½" hot and cold supplies
(not included). If using flexible supply
hoses, be sure to follow the manufac-
turer's instructions.
• For best service of the thermostatic mixing
valve, the incoming hot and cold water must
be at the same pressure.
This unit meets or exceeds the
following:
2
15 - 75 PSI
ASME A112.18.1
CSA B125.1
ASSE 1016
Listed by IAPMO for use in the
US and Canada
145 PSI
176°F*
8 GPM
2⅜"
1⅜"
• This valve is for a two-function installation.
Both outlets must be plumbed. Do not plug
either outlet. For a one-function installation,
see the special piping instructions.
• To prevent scald injury, the maximum output
temperature of the shower valve must be
no higher than 120°F. In Massachusetts,
the maximum output temperature can be no
higher than 112° F.
• Keep this booklet and the receipt (or other
proof of date and place of purchase) for
this product in a safe place. The receipt is
required should it be necessary to request
warranty parts.

Publicité

loading

Ce manuel est également adapté pour:

C 06456 0 serie