To send parameter information:
Pin1234, P1xxy...y , (send) xx= Parameter, y...y = Desired Value
To read parameter information:
Pin1234, P1xx? , (send) ? = asks to read parameter from device
Example:
To find out values set for the parameters 12, 14 and 15 for cabin 1
Send:
To set parameters 14 = 0 and 15 = 1 for cabin 2
Send:
3) Program commands via a handset connected to the DCP
i. All TOC DAU parameters can be remotely configured by numbers dialled on the
handset.
ii. Lift the phone off the handset and enter the commands to be configured using
the dial-pad:
The parameters shall be entered as follows with a synthesized audio voice played back
as a response
Enter command * 1xx * ---> AUDIO "The parameter x, x is ... (Value)."
The programming of a parameter is done as follows:
Enter command * 1xx#yy# * ---> AUDIO "Command correct."
xx = parameter number; yy = desired value (See table 4)
Examples:
1. Read the value of parameter 24.
Enter command * 124 * ---> AUDIO "Parameter 24, is ... 5".
2. Program parameter 24 of the equipment to value 4
Enter command * 124#4# * ---> AUDIO "Command correct".
The microphone volume (24) has been programmed at volume 4.