corp_U065-7474-B-DIVALI-VERRE-PREMIUM Page 38
- Position
running the screw heads
through slots.
- Before tightening the screws, line
up the markers on the wall support
with the 2 screws.
- Make sure that the supports are
level.
- Screw in the supports.
1.4.3 - Electrical connection
To facilitate connection, this appliance has been designed to re-
main upright during connection.
Connection rule
- The appliance must be supplied with 230V 50 Hz.
- The radiator's power supply must be connected directly to
the network after the single-pole disconnection mechanism, in
accordance with the installation rules. The radiator will be connected
to the mains with a 3-wire cable (Brown = Live, Blue = Neutral,
Black = Pilot wire) via a connection box.
- In damp rooms such as kitchens and bathrooms, the connection
box must be installed at least 25 cm from the ground. The installation
must be equipped with a 30mA differential circuit breaker-type
protection device.
- Connection to the earth is prohibited. Do not connect the
pilot wire (black) to the earth.
- If the power cable is damaged, it must be replaced by the
manufacturer, their after-sales service or any suitably qualified person,
in order to avoid any danger.
- If the pilot or piloted appliance is protected by a 30mA differential (e;g.:
bathroom), the pilot wire supply to this differential must be protected.
38
Black
the
supports,
If the electrical connection box
is located above the low wall
support, run the power cable
into the support to connect
it. This will prevent you from
pinching the cable.