INTRODUCTION
FH6/FH62 are protective headtops designed to be used alongside Scott Safety powered air
purifying respirators (PAPR) and one of three types of breathing hose.
FH6/FH62 are approved to EN 12941:1998/A2:2008, EN 166:2001, and AS/NZS 1716:2012. .
FH6 has a sliding polycarbonate visor and provides protection to EN166, marking 1 FT.
FH62 has a gold coated visor and provides protection to EN166, marking 1 FT.
When used with a Scott Safety PAPR, these headtops are designed to be used alongside
three types of breathing hose:
400mm Polyurethane self adjusting - Scott PU Stretch
850mm Polyurethane non-stretch - Scott PU non-stretch
800mm Ethylene Propylene Diene Monomer - Scott EPDM
The choice of hose is dependent on your own work practises/needs and is beyond the scope
of this manual. For further information contact Scott Safety customer services, details at the
rear of this manual.
The FH6 and FH62 headtops are adjustable to fit head sizes with a
horizontal measurement of 53cm - 65cm (measured at brow level, full circumference). Adjustment
is by means of an adjustable handwheel at the rear of the helmet.
FH6/FH62 are designed to allow a flow rate of between 160 litres per minute and 270 litres per
min, determined by accompanying Scott Safety PAPR systems EN 12941:1998/A2:2008 and
AS/NZS 1716:2012.
Please read this manual in conjunction with the respective PAPR manuals prior to use.
Note All new headtops are supplied with a protective film secured onto the visor. This film is for
transit purposes only and must be removed prior to the headtop being used.
FH6, FH62 Issue D