INSTALLATION SETTINGS MENU
The thermostat has a settings menu. To access the menu, hold the
first page of the menu will be displayed:
Now select a setting to be edited, using the key . Once the required setting has been selected,
push
to access the relevant editing phase (value flashing) and edit the value using the keys
or . Push the
key again to confirm the setting. To exit the settings menu, select "End" and
push the
key.
N.
Predefined values and other possibilities
01
°C/°F
°C
°F
02
__:__
24H
12H
03
dst
YES
no
AF
04
This menu can be used to set the temperature for the "anti-freeze" mode.
The default value for this setting is 5.0°C.
Edit the value using the
05
__._
Displaying of the value measured by the thermostat, with a deviation value.
To edit the value reads, push the
value.
Push the
ITCS
06
Activating/deactivating the automatic advance heating programming function
(see special functions section 3.3).
YES
no
Win
07
Activating/deactivating the window opening detection function (see special
functions section 3.4).
YES
no
08
Clr
This can be used to reinstate the default settings for the thermostat (time,
programs, etc.)
Confirm by holding down the
Type of degrees displayed
degrees Celsius
degrees Fahrenheit
Time format
(24:00)
(12:00 AM (morning) / PM (afternoon)
Automatic time change (summer <--> winter)
The time changes automatically.
The time must be edited manually.
Anti-freeze temperature
or
Calibration of the built-in sensor
key again to display the deviation added to the temperature value.
Intelligent Temperature Control System
Function activated.
Function deactivated.
Open window detection
Function activated.
Function deactivated.
Default setting
keys and confirm using
or
keys, and then the
key for 10 seconds.
[ 40 ]
key down for 5 seconds. The
.
key to save the