Authentication.
To reset the password and the user, follow these steps:
FACTORY
IP
idéo
SDI silence detector
AES setting
Adjustable from -60 to 0dBFS in 1dB increments
Adjustable from -12 to 0dBFS in 1dB increments
Adjustable from 1 to 120s in 1s increments
Adjustable from 1 to 120s in 1s increments
Button to save configuration changes.
1. Blank Threshold Filter.
The threshold "Blank threshold" defines the level below which the audio signal is considered as a silence. It is adjustable
from -60dBFs to 0dBFs in steps of 1dB. Enable, this filter generates an alarm of type Audio if there is no signal.
This filter uses the RMS level and not the PEAK level of the signal.
RAMI
WEB INTERFACE - next -
MONITORING
L
R
-40
-30
-24
-18
-12
-9
-6
-3
O dBFs
AES 1
AES 2
AES 3
PHONES
When starting the device, press the AES1 button (approx. 4 seconds) until the
AES2 indicator lights green.
steps of 1dB
Parameter
Check box
Blank Threshold
Enable/disable
Configuration page : user and password.
Required to access the configuration pages of the
device.
Do not forget to save your settings.
Mains
On
OPTION
POWER
Value
0 ~ -60
Threshold in dBFs
30
Comment
CSS300