Télécharger Imprimer la page

Orbegozo FO 1720 Manuel D'instructions page 9

Publicité

Les langues disponibles

Les langues disponibles

FO 1720 FO 2720 FO 3520
- 1 pressure regulator approved and indicated on the data plate.
- 1 flexible tube approved for gas, with a maximum length of 1.5 m.
- 2 screw clamps for the flexible tube.
Connect the flexible tube to the gas supply inlet on the stove and the regulator, ensuring the tightness by
means of the 2 screw clamps.
Place the bottle on a stable surface and assemble the bottle regulator. Make sure that the flexible tube does
not come into contact with the stove and that it is not subject to any twisting forces. After opening the
regulator, check there is no gas leak by applying soapy water with a brush on the joint of the flexible tube
with the cooker and the regulator. The appearance of bubbles means there is a gas leak.
The bottle replacement must be done far away from any source of flame.
CHECKING CONNECTION TIGHTNESS
After connecting the gas, the tightness of the joints must be checked. To do so, apply soapy water to the
joints; if bubbles appear it means there is a leak.
NEVER USE A FLAME TO DETECT GAS LEAKS
WARNINGS FOR USE
If the stove has been moved, it will be necessary to check that the burner caps are properly fitted.
The appliance runs on BUTANE or PROPANE gas 28‐30/37 mbar.
‐ The appliance and the gas bottle must be placed on a flat surface far away from flammable materials.
‐ Protect the bottle and the appliance from direct sunlight.
‐ The bottles must not be stored indoors, in an unventilated area, or in a cellar.
- This appliance is not intended for use by persons (including children) with reduced physical, sensory or
mental capabilities or lack of experience and knowledge, unless they are supervised by a competent person
during its use.
- Keep children well away from this appliance.
- PRECAUTION: For safety reasons, never leave packaging materials (plastic bags, cardboard, polyethylene
etc.) within the reach of children.
WARNING: do not move the appliance when in use or when still hot.
‐ Change the deteriorated or porous gas tubes and replace them before the expiry date indicated on the same
tube. The tubes must not be compressed, and must be installed so that they are not subject to any forces.
THEY MUST NOT come into contact with any hot part.
‐ All repairs and maintenance must be carried out by specialized personnel.
‐ Any modification or alteration could be dangerous.
The air required for combustion is 2.0 m3/h per every kW of nominal flow.
WARNING:
ACCESSIBLE PARTS CAN REACH VERY HIGH TEMPERATURES!
KEEP OUT OF CHILDREN'S REACH.
WARNING: after use, turn off the burner immediately.
IF YOU SMELL GAS:
‐ Turn off the burner
‐ Close the appliance gas supply (bottle tap)
‐ Contact your gas supplier or specialized personnel.
The support cannot be made of flammable materials and must resist a temperature of at least 90º C.
Warning: We advise you to check if your appliance has been properly installed. Also it is necessary to have
the appliance checked at least once a year to examine the state of the connection tube, taps, etc.