Technical features
Performance: ambient temperature 15°C
Ambient temperature
Temp. Water
Input/output
Glycol
-4°C /-8 °C
35%
1°C /-3°C
35%
7°C / 3°C
35%
11°C / 7°C
35%
19°C / 15°C
35%
Ambient temperature
Temp. Water
Input/output
Glycol
-4°C /-8 °C
35%
1°C /-3°C
35%
7°C / 3°C
35%
11°C / 7°C
35%
19°C / 15°C
35%
Ambient temperature
Temp. Water
Input/output
Glycol
-4°C /-8 °C
35%
1°C /-3°C
35%
7°C / 3°C
35%
11°C / 7°C
35%
19°C / 15°C
35%
Ambient temperature
Temp. Water
Input/output
Glycol
-4°C /-8 °C
35%
1°C /-3°C
35%
7°C / 3°C
35%
11°C / 7°C
35%
19°C / 15°C
35%
Version: 2020-01
Installation and maintenance manual
Maximum power 85 Hz
15°C
Power
Power ABS
in cold
Without pump
28.0 kW
33.1 kW
39.6 kW
44.2 kW
53.7 kW
Partial load 70 Hz
15°C
Power
Power ABS
in cold
Without pump
24.1 kW
28.6 kW
34.5 kW
38.7 kW
47.6 kW
Partial load 50 Hz
15°C
Power
Power ABS
in cold
Without pump
18.9 kW
21.7 kW
26.5 kW
29.9 kW
37.4 kW
Partial load 25 Hz
15°C
Power
Power ABS
in cold
Without pump
13.1 kW
15.8 kW
19.5 kW
22.1 kW
28.0 kW
TECUMSEH EUROPE S&L
2 av. Blaise Pascal, 38090 Vaulx Milieu
Tel.: +33 (0)4 74 82 24 00 - www.tecumseh.com
INFINEE chillers
Power ABS.
Total
9.4 kW
10.5 kW
10.4 kW
11.5 kW
11.8 kW
12.9 kW
12.9 kW
14.0 kW
15.6 kW
16.7 kW
Power ABS.
Total
7.4 kW
8.5 kW
8.1 kW
9.3 kW
9.1 kW
10.2 kW
9.8 kW
11.0 kW
11.5 kW
12.7 kW
Power ABS.
Total
5.1 kW
6.2 kW
5.3 kW
6.5 kW
5.9 kW
7.0 kW
6.2 kW
7.3 kW
7.0 kW
8.1 kW
Power ABS.
Total
3.2 kW
4.3 kW
3.5 kW
4.6 kW
3.7 kW
4.8 kW
3.9 kW
5.0 kW
4.2 kW
5.3 kW
Water flow
3
7.0 m
/h
3
8.5 m
/h
3
10.2 m
/h
3
11.4 m
/h
3
13.8 m
/h
Water flow
3
6.0 m
/h
3
7.4 m
/h
3
8.9 m
/h
3
9.9 m
/h
3
12.2 m
/h
Water flow
3
4.7 m
/h
3
5.6 m
/h
3
6.8 m
/h
3
7.7 m
/h
3
9.6 m
/h
Water flow
3
3.3 m
/h
3
4.1 m
/h
3
5.0 m
/h
3
5.7 m
/h
3
7.2 m
/h
ENGLISH
30