Note:
Technical parameters are measured at an ambient temperature of 32 °C and water temperature of 22 °C.
Attention:
Cooling unit may not be used under pressure!
Maximum height below water level: 200 cm (0.2 bar).
4.
Instructions for Temperature Control

4.1. Temperature Setting

Turn off the controller, press "△" "▽" button at the same time for 6 seconds, "Pd" appears. Then set number to
"95", afterwards, press the "ON/OFF" button to enter the menu.
Setting temperature window will show"F1~F9" and the test temperature window will show the number. Press
the "ON/OFF" button to choose "F1~F9", press the "△" "▽" button to increase or decrease the number.
F1: Temperature difference:
F2: Temperature correction:
F3: Start delay:
F4: Fan:
F5: Password:
F6: Defrost time:
F7: Defrost cycle:
F8: Highest temperature setting:
F9: Lowest temperature setting:
FB:Temperature to enter into defrost:
FC:Temperature to exit defrost:
FD:Fan start temperature:
FE:Fan stop working temp.:
Control plate
In working state, press "△" "▽" to adjust temperature.
Temperature control range
For example: highest temperature is 35 °C,lowest temperature is 5 °C,that means temperature control range
is 5 °C to 35 °C.

4.2. Cooling Mode

1. When the water temperature in the water tank is higher than the adjusted set temperature + temperature
difference, the compressor and fan will start to work and the refrigerating indicator light is on. At this time,
the machine starts cooling.
9
1~15 °C
-15~15 °C
0 -5 minutes
0 - 3
0 -255
1 - 255 minutes
10 - 255 minutes
setting temperature ~70 °C
-19 °C ~setting temperature
19 °C~
~35 °C
0~50 °C
0~50 °C
factory setting: 1 °C
factory setting: 0 °C
factory setting: 5 minutes
factory setting: 02
factory setting: 95
factory setting: 3 minutes
factory setting: 45 minutes
factory setting: 36 °C
factory setting: 5 °C
factory setting:- 5 °C
factory setting:20 °C
factory setting:48 °C
factory setting:38 °C