CODE
POSSIBLE CAUSE
7
Regulator is not adjusted correctly
for accessory being used
8
Prolonged excessive use of air
9
Compressor is not large enough for
accessory
10
Hole in air hose
11
Check valve restricted
12
Air leaks
13
Regulator is damaged
14
Motor overload protection switch
has tripped
15
Tank pressure exceeds pressure
switch cut-in pressure
16
Extension cord is wrong length or
gauge
17
Loose electrical connections
18
Possible defective motor
19
Paint spray on internal motor parts
20
Fuse blown, circuit breaker tripped
POSSIBLE SOLUTION
It is normal for some pressure drop to occur when an accessory is used, adjust the regulator
as instructed in Regulator under Features if pressure drop is excessive.
NOTE: Adjust the regulated pressure under flow conditions while accessory is being used.
Decrease amount of air usage.
Check the accessory air requirement. If it is higher than the CFM or pressure supplied by your
air compressor, a larger compressor is needed to operate accessory.
Replace air hose.
Contact a D
WALT factory service center or a D
E
Tighten fittings.
Replace.
Refer to Motor Overload Protection under Features. If motor overload protection trips
frequently, contact a D
WALT factory service center or a D
E
Motor will start automatically when tank pressure drops below cut-in pressure of pressure
switch.
Check for proper gauge wire and cord length. Refer to the Extension Cords paragraph in
the Installation section.
Contact a D
WALT factory service center or a D
E
Contact a D
WALT factory service center or a D
E
Contact a D
WALT factory service center or a D
E
operate the compressor in the paint spray area. See flammable vapor warning.
1. Check fuse box for blown fuse and replace as necessary. Reset circuit breaker. Do not
use a fuse or circuit breaker with higher rating than that specified for our particular branch
circuit.
2. Check for proper fuse. You should use a time delay fuse.
3. Check for low voltage conditions and/or proper extension cord.
4. Disconnect the other electrical appliances from circuit or operate the compressor on its
own branch circuit.
16
WALT authorized service center.
E
WALT authorized service center.
E
WALT authorized service center.
E
WALT authorized service center.
E
WALT authorized service center. Do not
E