AUXILIARY INPUT AND OUTPUT CONNECTIONS
CAUTION: The remote connections are insulated from the network power by a "reinforced"
type insulation (reinforced insulation according to EN 60730-1). Therefore it is recommended to
make electrical connections with a type of cable that guarantees double or reinforced insulation,
using insulated voltage-free contacts for the digital inputs.
Nettuno has various auxiliary connections located on the I/O board. The following diagram identifies
the various connections.
4÷20mA PRESSURE
SENSOR
0-10V ANALOGUE
INPUT
DIGITAL RELAY OUTPUTS
35
Insert the cables of the auxiliary
devices via the central cable clamps in
plastic. Use the relative cable guides to
.
keep wiring tidy
CABLE
GUIDE
CABLE CLAMPS FOR
AUXILIARY INPUTS
DIGITAL INPUTS
SERIAL PORT
RS 485
SERIAL PORT
RS 485