OPTIONAL CONNECTIONS
E
xternal lock release activation.
The lock release can be activated at any moment by using an external push
button, that must be connected between 'AP' and ' ' terminals of the door
panel.
Door opening timed at 3 or 15 seconds, with the help of the dip switch
SW1-2 (see page 112).
This function will allows to exit from the building being not necessary the use
of a key.
A
uxiliary devices activation.
To activate auxiliary devices the use of a SAR-12/24 relay unit will be required. If this device is shared
for all the Platea Plus monitors, link their A1 terminal and use just one relay unit. In case that each
monitor has its own application use a SAR-12/24 relay unit for each monitor and don't link the A1
monitor terminals.
To activate this function, press
monitor push button at any moment with no dependence of the
handset position.
Usual applications are the activation of stairs light, second lock release, ...
Platea Plus
CN4
_
+
V
V
Malla
A
D
A1
in
out
To distributor/
door panel.
( )
The neutral supply from the stairs light will be wired through the relay contacts SAR-12/24, the maximum current for stairs
*
light will be 1.8A.
The use of a TF-104 transformer will be necessary to activate a second lock release.
Platea Plus
CN4
_
+
V
V
Malla
A
D
A1
in
out
To distributor/
door panel.
145
Door panel
–
AP _
NC
NA
C
To stairs light
push button
SAR-12/24
IN
IN
P
220 Vac/
( )
*
1.8A max.
N
NC
NA
C
TF-104
SAR-12/24
PRI SEC
IN
IN
~
~
~
~
Main
Lock release
Vac.
146
A
ctivation of a second camera.
The use of a SAR-12/24 relay will be required to activate a second camera and an internal
modification on the monitor shall be done, as it's described on page 120. This facility disables the
intercom function. If both functions are required, use A1 terminal to activate the second camera.
To activate this function, press
monitor push button at any moment with no dependence of the
handset position.
If this device is shared for all the Platea Plus monitors, link their 2C terminal and use just one relay
unit. In case that each monitor has its own camera use a SAR-12/24 relay unit for each monitor
and don't link the 2C monitor terminals.
This push button can be used to activate other auxiliary devices, as the A1 terminal is used.
Usual applications are the surveillance of the elevator entrance, reception hall, ...
Platea Plus
CN4
_
+
V
V
Malla
A
D
2C
in
out
C
onnecting the Platea Plus monitor
to a video recorder or TV.
If your TV or video recorder have a SCART connector, it will
be possible to view the picture from the door panel on
the TV screen.
Remove the end of line jumper, that's placed on the CN4
connector. Connect the coaxial cable between terminals
17 (shield) and 20 (hot) of the SCART connector.
OPTIONAL CONNECTIONS
nd
2 Camera
NC
NA
C
SAR-12/24
IN
IN
Platea Plus
CN4
_
+
V
V
Malla
A
D
in
out