Franklin Electric Co., Inc.
Oklahoma City, OK 73157-2010
www.lg-outdoor.com
E N G L I S H
customerservice@lgpc.com
EN
This instruction sheet provides you with the information required to
safely own and operate your product. Retain these instructions for
future reference.
The product you have purchased is of the highest quality
workmanship and material, and has been engineered to give you long
and reliable service. These products are carefully tested, inspected,
and packaged to ensure safe delivery and operation. Please examine
your item(s) carefully to ensure that no damage occurred during
shipment. If damage has occurred, please contact the place of
purchase. They will assist you in replacement or repair, if required.
read tHese instructions careFully BeFore atteMPtinG
to install, oPerate, or service your Product. Know
tHe Product's aPPlication, liMitations, and Potential
HaZards. Protect yourselF and otHers By oBservinG
all saFety inForMation. Failure to coMPly witH tHese
instructions could result in Personal inJury and/or
ProPerty daMaGe!
The power control center (Figure 1) provides three power options:
•
two 110-volt outlets on a digital, programmable timer
•
two 110-volt outlets that are constantly on
•
one low-voltage outlet on a digital, programmable timer
Maximum amperage for the 110-volt outlets is 10 amps total. The low-
voltage outlet has a maximum output of 150 watts and is ideal
for running Egglites (or any 12 VAC lights up to 150 watts) in either an
underwater or dry application.
110 VAC timer and outlets
Minuterie 110 VCA et les débouchés
Temporizador 110 V y salidas
110 VAC continuous-duty outlets
110 VCA points de service continu
110 V salidas de servicio continuo
Figure 1 • Figure 1 • Figura 1
1
Power control center
Model Pc50 and Pc50-15
convertisseur Power
control center –
Modèles Pc50 et Pc50-15
centro de control
de Potencia Modelo Pc50 y
Pc50-15
ENGLISH
descriPtion
12 VAC timer and connections
12 VCA minuterie et les connexions
12 V Temporizador y Conexiones
Mounting bosses on back
Patrons de montage sur le dos
Jefes de montaje en la parte posterior
saFety Guidelines
warninG: If installation involves running wiring through a building
structure, special wiring methods are needed. Consult a qualified
electrician. To reduce the risk of electrical shock, connect the product
to a properly grounded, grounding-type receptacle. Never remove or
disable the grounding pin of the cord plug. The National Electric Code
and many local building codes require the use of a ground fault circuit
interrupter (GFCI) on the branch circuit supplying fountain equipment
rated above 15 volts.
To reduce the risk of fire, replace only with a 15A fuse having a
voltage rating of 125V or higher.
Do not use with dimmers.
Disconnect all power supplies before servicing.
Adhere to the guidelines of the National Electric Code (NEC) or
Canadian Electric Code (CEC) and any other national, state, and local
electric, plumbing, and building codes for ALL installations. Check
with the appropriate agencies or a water systems professional for
information. The installation of this product must be in accordance
with applicable regulations.
installation
1. Choose a dry and protected area to locate the power control
center.
2. Mount the power control center at least 3 feet above ground
level, using the bosses on the back for convenience.
3. Plug the power control center directly into a properly grounded,
grounding type receptacle equipped with a GFCI.
oPeration
note: The minimum setting time is one minute and the maximum
setting time is 24 hours. There are a total of six ON-OFF settings. The
light will stay lit during the programming for 1 minute. Pressing the
MODE button (Figure 2) scrolls through the following options:
•
PRO – Programming mode
•
RUN – Starts the automatic program
•
ON – Manual operation
•
OFF – Turns timer and outlets off
1.
Connect the power cord to a 120 VAC, 60 Hz wall outlet.
2.
Press the RESET buttons (one under each display) once to
clear all programs. Display will show the number "0" in all
positions. Verify unit is in the "OFF" mode.
3.
Your PC50 Power Control unit is shipped from the factory
RUN
ON
(Left Display 110 VAC)
(Gauche Affichage 110 VCA)
(Pantalla Izquierda 110 V)
Figure 2 • Figure 2 • Figura 2
WARNING
WARNING
WARNING
RUN
ON
(Right Display 12 VAC)
(Droite Affichage 12 VCA)
(Pantalla Derecha 12 V)