Troubleshooting Guide - EINHELL GC-DW 900 N Mode D'emploi D'origine

Masquer les pouces Voir aussi pour GC-DW 900 N:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 12
Anleitung_GC_DW_900_N_SPK7__ 25.06.13 10:26 Seite 11

10. Troubleshooting guide

Faults
The equipment does not start
The equipment does not pump
The equipment does not cut out
Insufficient pumping rate
The equipment switches off after
briefly running
Cause
-
Power supply not connected
-
Floating switch does trigger
-
Intake sieve clogged
-
Discharge hose kinked
-
Floating switch cannot sink
-
Intake sieve clogged
-
Performance reduced due to
heavily contaminated and
abrasive water impurities
-
Motor circuit-breaker switches
the equipment off due to
excessive water contamination
-
Water temperature too high;
motor circuit-breaker switches
the equipment off
GB
Remedy
-
Check power supply
-
Raise position of floating switch
-
Clean intake sieve with water jet
-
Unkink the hose
- Lower the position of the floating
switch.
-
Clean intake sieve
-
Clean equipment and replace
wear parts
-
Unplug power plug and clean
equipment and shaft
-
Ensure that maximum
permissible water temperature
(35 °C) is not exceeded
11

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

41.709.64

Table des Matières