10.7 Electrical Installation

4 Nm
Kabelverschraubung: M25x1,5
für Kabel Ø 10 – 17 mm
-
Cable gland: M25x1,5
for cable Ø 10 – 17 mm
-
Entrée de câble: M25x1,5
de câble Ø 10 – 17 mm
-
pour
Tighten the fastening bolts after assembly! Note the maximum
tightening torque for this (T
Conventional bolts M8 with flat bearing face can be used for fas-
tening the navigation lights (e.g. cylinder head bolts or hexagon
bolts). Corresponding bolts can be ordered as accessories (see
chapter 11). When selecting the material, please note the mate-
rial information cited below (see chapter 10.9).
The operating life expectancy of the LEDs is subject to the influ-
ence of external temperatures that occur (see chapter 16). Suffi-
cient heat dissipation must be ensured! Avoid close enclosure of
the navigation lights.
The electrical connections are made in accordance with the ap-
plicable regulations of electrical engineering.
The corresponding current circuits must be disconnected before
starting work.
The navigation light housing is to be opened for
Therefor the four screws above the housing are to loose.
Subsequently, the upper part of the navigation light can be
opened in forward direction
Route the installation cable through the cable entries into the
interior of the navigation light to the connection
The maximum cable length must not exceed 400 m. The outside
diameter of the cable outer jacket is limited by the cable gland.
The cross-section of the cables must be at least 1.5 mm
limited by the connection terminal max. 2.5 mm
/
/
Page 16 of 24
= 8 Nm).
max
(see chapter 9).
terminal.
2
in size.
9420119300_en Rev. 3
installation.
2
and are