Signal quality of the Buzzer
With DIP 4 in the receiver is in ON position, it indicates the signal quality of the buzzer. It beeps from 1 to
5 and it indicates signal quality and each 12 seconds inf the PASSIVE CONTROL MEMORIZATION, while
120 seconds each in the ACTIVE CONTROL MEMORIZATION: 1 beep not good signal, 5 beeps very good
signal.
LED-RX1 Signal quality
The l.e.d. 1 of the receiver flashes when one Tx is on alamr (you can test when you open a N.c. contact of
the terminal board of the TX). The l.e.d. flashes from 1 to 5 times and it indicates the signal quality of the
transmission: 1 flash not good signal, 5 flashes very good signal
Check with DIP-1 OFF in the Tx and in the RX
If you push P2 of the receiver for 5 seconds, the receiver will work in CHECK : the buzzer will sound to
confirm the operation. This operation can test the transmission of the TX. The receiver will be in CHECK for
5 minutes until P2 on the RX will be pressed. During the CHECK operation the receiver will sound constantly
to indicate the good work of the TX while it will beeps for 3 times to indicate the uncorrect transmission of the
TX. When the receiver is out of the CHECK operation, the receiver will beep for a long time if the transmission
with the TX are correct while it will beep for 3 times if there is some problems with the tx. During the CHECK
operation, the gate can move.
Battery not charged
The receiver will be for 3 times if the battery of one TX is not working properly:
The beep is every 12 sec in the PASSIVE CONTROL MEMORIZATION
The beep is every 120 sec in the ACTIVE CONTROL MEMORIZAION
The beep is every time it appears the safety
Test
When you activate the TEST with TEST INPUT (see previous connections), the receiver get in allarm all Tx,
and it put the output in the NORMAL STATUS when the test is not activated.
OUT1 y OUT 2 of the receiver
The outputs are N.C. or 8,2k in case of not alarm. There is a l.e.d. to each output which is normally lit on.
If you use a resistive 8,2k output and it is in alarm the contact is normally closed. To select the output use
JUMPER N/R1 nc/na and JUMPER C/R2 NC/NA below the relays.