TRANSCEIVER
Memorization when the control
has been activated. DIP-1 OFF
in Tx and Rx
The system is used for safety to the automation
according to the laws only if the test will be done
at the beginning of each movements of the inputs.
TEST INPUTS
Connect to the test connections COMMON
(negative) and FOTOTEST output from the control
unit of the gate.
With DIP-2 of the RX in OFF the Receiver will
ccheck the transmission of all TX when there
is tension in all inputs.
DIP-2 of the RX in ON position in the receiver,
will check all transmissions in case the
tension is missing.
In this case, there is an active check of the safety
and of the installation according to the law, the
receiving of the signal in the TX is always active,
and there is a higher consume of the batteries.
In case of 2 batteries LR06 AA 1,5 V
the battery life is approximately 12 months.
Example of the installation
TX
Check of the passive control
DIP -1 in ON in Tx and Rx
There is a passive check available called "CHECK
OF THE STATUS " of the safeties, the Tx receive
the signal each 12 sec. If after 30 seconds the
receiver doesn't receive any signal from the
transmitter, the RECEIVER put in alarm the output
to the corresponding Tx.
Installation
If you decide this operating installation put DIP-1 in
OFF in the transmitter and in the receiver, in the way
you use the CHECK installation and then DIP-1 ON
in the transmitter and in the receiver
When you switch on the installation, the receiver will
wait the constant transmission of the TX, and it will
activate the input in 10 seconds, and if the Tx are not
available or don't work, wait for a while before the
receiver will check all the transmitters. (red L.E.D.
turn off). This is also for the TEST (PHOTOTEST)
from the control unit, the output will activate within
10 seconds.
With this installation the battery life will be until 24
months.
N.C. / 8,2k
TX
-11-
TX
RX
GB