STEP 1:
Actuate RESET button through the access hole.
Press and hold Reset button until the LED
flashes fast (approximately 5 seconds). See
Figure 5.
STEP 2:
Release the Reset button for 1 second (Fast
flashing continues). Press and hold Reset for 1
second until fast flashing stops. If the blue LED
does not respond with the two-blink sequence,
please repeat the RESET procedure.
CLEANING LENS
STEP 1:
Locate the end cap with the arrow marks on it,
indicating that the end cap is removable. See
Figure 6.
STEP 2:
Grab the lens section next to the end cap and
pull lens and end cap together downward
gently until end cap just clears luminaire
(about 3" to 4" from original position). See
Figure 7.
STEP 3:
Disengage the other end of the lens from the
opposite end cap by pulling lens away from
end cap. See Figure 7. Once lens is removed,
perform cleaning.
STEP 4:
After cleaning is complete insert lens back
into fixed end cap. Push the removable end cap
upward into the housing and using a gentle
rocking motion engage the end cap to retention
clip. Check removable end cap for any visible
gap between the end cap and end panel. If
necessary push end cap against the end panel
to eliminate gaps.
Check lens for any visible gap between the
lens and luminaire. If necessary push lens
upward at gap location to seal magnetic foam
to luminaire. See Figure 8.
TROUBLESHOOTING:
Out of the box, if the light does not turn on
when power is applied:
Check Wiring with power off
If wired correctly, check to see if Blue
LED has a double blink pattern. If not,
please proceed to RESET procedure.
If Blue LED is blinking, then perform a
RESET (See RESET section).
If Blue LED is on solid or off, call Cree
Lighting Customer Service.
3 of 4
1
Fixed End Cap
If you have done a RESET, and the light
is still off, call Cree Customer Service.
If light is unresponsive, use Cree Lighting
Configuration Tool to verify configuration.
EMERGENCY DRIVER CHECK
NOTE: For short-term testing of the emergency
function, the battery must be charged for at
least one hour. The emergency driver must be
charged for at least 24 hours before conducting
a long-term test.
STEP 1:
When AC power is applied, the charging
indicator light is illuminated, indicating the
battery is being charged. When power fails,
the emergency driver automatically switches
to emergency power, operating the LED array.
When AC power is restored, the emergency
driver returns to the charging mode.
STEP 2:
Although no routine maintenance is required
to keep the emergency driver functional, it
should be checked periodically to ensure
that it is working. The following schedule is
recommended:
• Visually inspect the charging indicator
light monthly. It should be illuminated.
• Test the emergency operation of the
fixture at 30-day intervals for a minimum
of 30 seconds. When the test switch
is depressed, the LED array should
operate.
• Conduct a 90-minute discharge test once
a year. The LED array should operate for
at least 90 minutes.
If the luminaire fails any of these checks,
consult service personnel.
REFER ANY SERVICING INDICATED BY THESE
CHECKS TO QUALIFIED PERSONNEL
EMERGENCY DRIVER AND AC DRIVER
MUST BE FED FROM THE SAME BRANCH
CIRCUIT.
FCC NOTICE
CAUTION: Changes or modifications not
expressly approved could void your authority to
use this equipment.
This device complies with Part 15 of the
FCC Rules. Operation to the following two
conditions: (1) This device may not cause
harmful interference, and (2) this device must
accept any interference received, including
interference that may cause undesired
operation.
The LED in the front of this device operates
within Risk Group 1 levels per IEC 62471.
This device has been tested and found to
comply with the limits for a Class A digital
device, pursuant to Part 15 of the FCC
Rules. These limits are designed to provide
reasonable protection against harmful
interference when the device is operated
in a commercial environment. This device
generates, uses, and can radiate radio
frequency energy and, if not installed and used
in accordance with the instruction manual,
may cause harmful interference to radio
communications. Operation of this device in
a residential area is likely to cause harmful
interference in which case the user will be
required to correct the interference at his own
expense.
INDUSTRY CANADA STATEMENT
This device complies with Industry Canada
licence-exempt RSS standard(s). Operation is
subject to the following two conditions: (1) this
device may not cause interference, and (2) this
device must accept any interference, including
interference that may cause undesired
operation of the device. In addition, this device
complies with ICES-003 of the Industry Canada
(IC) Regulations.
Le présent appareil est conforme aux CNR
d'Industrie Canada applicables aux appareils
radio exempts de licence. L'exploitation est
autorisée aux deux conditions suivantes : (1)
l'appareil ne doit pas produire de brouillage, et
(2) l'utilisateur de l'appareil doit accepter tout
brouillage radioélectrique subi, même si le
brouillage est susceptible d'en compromettre
le fonctionnement.
RF EXPOSURE NOTICE:
To comply with the FCC/IC RF exposure
compliance requirements, this device and its
antenna must not be co-located or operating
to conjunction with any other antenna or
transmitter.
This equipment shall be installed and operated
with minimum distance 5 cm between the
radiator & your body. No other antenna is
authorized for use with this product.
Pour correspond aux requis d'exposition au
FCC/IC RF, cet appareil et son antenne ne
doivent etre localisee tout pret ou operer
en conjunction ave d'autres antennes ou
transmetteurs. Cet equipement doit etre
installe et opere avec une distance minimum
5 cm entre l'emetteur et votre corps. Aucune
autre antenne externe n'est autorisee a etre
utilise avec ce produit.
LPN00678X0004A0_B

Publicité

loading

Ce manuel est également adapté pour:

Smartcast r14-sc1Smartcast zr22-sc1Smartcast zr24-sc1