4
Large Trim Ring
Test Switch
Small Trim Ring
6
SUSPENDED MOUNTING
STEP 1:
Attach customer supplied cables to the (4)
T-bar clips located in the corners of the
housing. See Figure 1.
NOTE: The hole in each clip should be used to
attach the cable
STEP 2:
Attach cables to mounting surface using
customer supplied hardware. Ensure that
mounting surface can support the luminaire.
SMARTCAST
SETUP
®
NOTE: Cree Lighting recommends reviewing
the Cree Lighting SmartCast Technology
Wireless Deployment Guide prior to installing
luminaires with Cree Lighting SmartCast
Technology.
NOTE:
• Visit Cree Lighting's website for the
guide:
www.creelink.com/exLink.asp?2361356
4OH88E44I39771048&view=1
2 of 4
T-Bar Clips
bent upward,
rotated
outward, and
engaged with
the grid
Ceiling
End Cap
Arrow Marks
NOTE: SmartCast luminaires must be
installed on unswitched AC power. Constant
power is required to maintain all luminaires
on the Smartcast network.
STEP 1:
Disconnect power to circuit by turning circuit
breaker OFF before installation.
STEP 2:
Remove the screw on the cover of the
junction box and bring in appropriate power
supply to the junction box using one of the
knock-outs. See Figure 3.
STEP 3:
Wire luminaire per "Electrical Connections"
section and push all leads into the junction
box. Reattach junction box cover that was
removed in Step 2. Make sure no wires are
pinched.
STEP 4:
Install test switch assembly into ceiling by
drilling a 1" hole into the ceiling.
3
5
7
1
2
DO NOT Rotate
Lens Into This
Arrow Marked
End Cap
STEP 5:
Unscrew the small trim ring and place test
switch assembly through the ceiling. See
Figure 4.
STEP 6:
Secure the test switch assembly by screwing
the small trim ring removed in Step 5 back
onto the test switch assembly. Tighten the
larger trim ring above the ceiling until it is
snugged tight against the ceiling.
See Figure 4.
STEP 7:
Switch the circuit breaker on.
STEP 8:
Make sure the WIM blue LED has a double
blink pattern. If not, please proceed to
Troubleshooting section. Otherwise, you
can proceed to commission the zone
controller. Please refer to the Smartcast
documentation for details. See Figure 5.
Junction Box
Cover
Reset Button
Motion Sensor
Ambient Light Sensor /
Blue LED indicator
Zone
LPN00678X0004A0_B
®