IMPORTANT SAFEGUARDS
When using electrical equipment, basic safety precautions should always
be followed including the following:
READ AND FOLLOW ALL SAFETY
INSTRUCTIONS
1.
DANGER- Risk of shock- Disconnect power before installation.
DANGER – Risque de choc – Couper l'alimentation avant
l'installation.
2.
This luminaire must be installed in accordance with the NEC or
your local electrical code. If you are not familiar with these codes
and requirements, consult a qualified electrician.
Ce produit doit être installé conformément à NEC ou votre code
électrique local. Si vous n'êtes pas familier avec ces codes et
ces exigences, veuillez contacter un électricien qualifié.
3.
Suitable for Damp Locations.
Convient aux emplacements humides.
4.
Access above ceiling required. Do not install insulation within
3 inches (76 mm) of any part of the luminaire.
Acces requis au-dessus du plafond. Ne pas mettre l'isolant a
moins de 76 mm (3 po) de toute partie du luminaire.
5.
Vapor barrier must be suitable for 90C.
Le pare-vapeur doit convenir pour 90 °C.
6.
No user serviceable parts.
Pieces non reparables par l'utilisateur.
7.
Inherently protected.
Protection inherente.
8.
Do not handle energized module with wet hands or when standing
on wet or damp surfaces, or in water
SAVE THESE INSTRUCTIONS
FOR FUTURE REFERENCE
• The ZR-SC1 Series of recessed troffers is for non-insulated ceiling
applications using T-Bar ceiling grid, drywall grid adaptors, and
suspended mount.
• Designed for use in 120-277V 50-60 Hz protected circuit (fuse box,
circuit breaker). Supply wire sized as per NEC or governing code(s),
90C rated.
• Make sure to cap off all unused leads.
TO INSTALL:
1
1 of 4
T-Bar Clips
ZR Series with SmartCast
Emergency Driver and Removable Lens
Includes: ZR14-SC1, ZR22-SC1 and ZR24-SC1
ZR14-SC1
ZR22-SC1
ZR24-SC1
• Lens and removable end cap may shift during installation. Press
center of lens to engage magnet strip and push the end cap against
the end panel to eliminate the gap after installation.
• IMPORTANT: To avoid damage to the lens or housing during
installation, make sure fixture is supported near the centers of both
long sides of the housing when lifting. Do not lift fixture from one
end only.
T-Bar Clip Hole
Technology
®
Specification Troffers with
INSTALLATION INSTRUCTIONS
INSTRUCTIONS D'INSTALLATION
T- BAR CEILING MOUNTING
STEP 1:
Bring the ZR troffer into the T-bar
ceiling panel. See Figure 1 for location
of the T-bar clips on end panels of
troffer.
STEP 2:
Bend clips upward and rotate outward
to engage with T-bar support grid. See
Figure 2. Secure luminaire to grid in
compliance with state and local codes.
LPN00678X0004A0_B