TROUBLESHOOTING PROCEDURES FOR TORNADO MINI
Issue
Cause
After installation,
1. The power source is not turned ON.
the unit doesn't
work.
2. The power line and the cable locking connector
is not connecting properly.
3. The switch board and control board wirings are
disconnected.
4. On the switch board, Black/White wire or White
wire is disconnected.
5. The switch board or control board is defective.
Light works,
1. The blower is defective, possible seized.
but motor is not
2. The thermally protected system detects if the
turning.
motor is too hot to operate and shuts the motor
down.
3. Damaged capacitor.
The unit is
1. The blower is not secure in place.
vibrating.
2. Damaged blower wheel.
3. The hood is not secured in place.
The motor is
1. Defective halogen bulb.
working, but the
2. The light bulb is loose.
lights are not.
The hood is
1. The hood might be hanging to high from the
not venting out
cook top.
properly.
2. The wind from the opened windows or opened
doors in the surrounding area are affecting the
ventilation of the hood.
3. Blocking in the duct opening or duct work.
4. The direction of duct opening is against the wind. 4. Adjust the duct opening direction.
5. Using the wrong size of ducting.
Metal filter is
1. Metal filter is loose.
vibrating.
2. Spring clip is broken.
What to do
1. Make sure the circuit breaker and the unit's
power is ON.
2. Check the power connection with the unit is
connected properly.
3. Make sure the wirings between the switch
board and control board are connected
properly.
4. Make sure the Black/White wire or White wire
connects properly.
5. Change the switch board or control board.
1. Change the blower.
2. The motor will function properly after the
thermally protected system cool down.
3. Change the capacitor.
1. Tighten the blower in place.
2. Change the blower.
3. Check the installation of the hood.
1. Change the halogen bulb.
2. Tighten the light bulb.
1. Adjust the distance between the cook top and
the bottom of the hood within 24" to 34" range.
2. Close all the windows and doors to eliminate
the outside wind flow.
3. Remove all the blocking from the duct work or
duct opening.
5. Change the ducting to at least 6" or higher.
1. Change the metal filter.
2. Change the spring clip.