AIR SUPPLY
Air
Length of Pipe (ft.)
Flow
CFM
50
50
50
50
10
1/2"
20
3/4"
30
3/4"
40
1"
50
1"
70
1"
Never mount oil and water extractor on or near the air com pres sor.
During compression, air temperature is greatly increased. As the air cools down to room tem per a ture, moisture condenses in the air line, on
its way to the spray gun. Therefore, always mount the oil and water extractor at a point in the air supply system where the compressed air
temperature is lowest.
Drain air lines properly.
Pitch all air lines back towards the com pres sor so that con densed mois ture will flow back into the air receiver where it can be drained off.
Each low point in an air line acts as a water trap. Such points should be fitted with an easily accessible drain. See diagram above.
TYPES OF INSTALLATION
This spray gun is rugged in construction, and is built to yield exceptional value. The life of this product and the efficiency of its
operation depend upon a knowledge of its construction, use and maintenance.
HVLP
Fluid
Siphon Cup
HVLP
Fluid
Fluid
Siphon Cup
Siphon Cup
SX80B
SX80B_082906.indd 3
100
100
100
100
150
150
150
150
200
200
200
200
3/4"
3/4"
3/4"
3/4"
3/4"
3/4"
1"
1"
1"
1"
1"
1"
1"
1"
1"
1-1/4"
1-1/4"
Fluid Control Screw
Air Inlet
Atomization
Pressure
Gauge
Air Hose
Fluid Control Screw
Air Inlet
Atomization
Pressure
Cup
Gauge
Regulator
Air Hose
Air Hose
Pitch pipe back
toward air receiver
Compressor Unit
Drain
Drain
Drain
Oil and Water Extractor should be at least 25 ft.
SIPHON FEED CUP HOOKUP
Air pressure for atomization is reg u lat ed at ex trac tor.
Amount of fluid is adjusted by fluid control screw on gun,
viscosity of paint, and air pressure.
Oil and
Water
Extractor
PRESSURE FEED CUP HOOKUP
For
fine
Oil and
Air
pressure
Water
ex trac tor; fluid pressure at cup regulator. For heavy
Extractor
fluids and internal mix nozzle spraying, fluid adjusted by
control screw on gun.
3
Install drain at
Install drain at
Install drain at
each low point
25 Feet
or More
from the compressor, farther if possible.
finishing
with
limited
for
atomization
is
Oil & Water
Extractor
Drain
Drain
Drain
spraying.
reg u lat ed
at
rev. 08/29/06
9/5/06 1:38:18 PM