9. RF commands programming
This programming can be done only after having turned the appliance
off and on or at the end of a closing cycle (end of the operating time).
To change the keys-RF commands configuration, proceed as follows:
1. Press SW1 (RF commands programming key - see fig.2.2). The
appliance beeps twice slowly signalling the beginning of the
programming phase.
2. Using an already programmed remote control, press in sequence
the keys corresponding to the Local Open, Local Close, Centralized
Open, Centralized Close, and Stop commands; after every learning
a number of beeps equal to the number of already programmed
commands will be emitted.
It is compulsory to assign a key position only to the "Local Open"
and
"Local Close" commands; the remaining assignments are
facultative. To skip a key position, press SW2 (times programming
key - see fig.2.2) instead of the remote control key.
3. At the end of the learning phase, the procedure ends automatically
(two slow beeps will be emitted) and you can return to normal
mode.
!
q If you make a mistake (for instance more commands assigned to
the same key), a number of short beeps will be emitted at the end
of the programming phase. In this case, it is possible to re-program
the keys starting from the one to which the "Local Open" command
has been assigned.
q If, after entering the learning phase, no key is pressed within 15
seconds, the procedure ends automatically (time-out); any
previous learning will remain valid.
q If you make a mistake, quit the procedure by pressing SW1 (RF
commands programming key - see fig.2.2): even in this case any
previous learning will remain valid.
If you want to change the parameters after the installation of the
module and the latter is not easily accessible, the procedure can be
done via radio using an already programmed remote control.
a - Press keys 1-4-5-8 simultaneously (TR14) or all keys (TR2 or
TR4) until hearing a short beep, then release the keys.
b - Within 5 seconds, repeat the operation while holding the keys
pressed until hearing two short beeps followed by two long beeps
signalling the beginning of the learning phase.
Now proceed as described above and remember that you have to
press again keys 1-4-5-8 (TR14) or all keys (TR2 or TR4) to skip a
key position.