6.2 Subsequent programming
To program other remote controls in a second time, turn the module
off and on or wait the end of a close cycle (end of the operating time),
then proceed as follows.
1. Press keys 1-4-5-8 simultaneously (TR14) or press all keys when
using an already programmed TR2 or a TR4, until a short beep
followed by a continuous sound is emitted signalling that the
learning phase is in progress.
2. Press keys 1-4-5-8 simultaneously (TR14) or all keys (TR2 or TR4)
of the new remote control to be programmed, until LED and buzzer
turn off for a short time before turning on again.
3. Now press any key of the remote control to be programmed until
LED and buzzer will turn off for a short time before turning on
again.
Even in this case, it is possible to program more remote controls by
repeating steps 2 and 3 until the sound alarm remains activated.
The learning phase ends by pressing the clear key SW3 or
automatically about 25 after the last storage.
6.3 Clearing a remote control
1. With the module turned on, press and hold the SW3 key: LED and
buzzer will turn on with a continuous sound.
2. Hold SW3 and press any key of the remote control to be erased.
LED and buzzer will turn off shortly confirming that the remote
control has been cleared.
To clear more remote controls, repeat step 2 while holding SW3.
7. Access control management
The Aprimatic remote controls are supplied already programmed with
a unique serial number .
Without programming interventions after the purchase by installers
equipped with the Aprimatic special tools, access control operations
can be directly managed by programming the first remote control. This
standard mode guarantees
rolling code) for any type of installation.
Access operations can also be managed in other 3 modes with
different functional and safety characteristics. These 3 modes have to
be programmed by qualified installers equipped with the special
Aprimatic programming tools: Apricot Manager Coding Unit and/or
Software for the access control management.
maximum safety conditions (hopping