HOW TO SETUP:
For both models all points are identical, except for the display messages: displays are shown on the left side.
To select any of the functions, press the MODE button until the required function is shown on the display
or use the DOWN and UP buttons to browse the menu.
Select the function with the ENTER button.
Use DOWN and UP buttons to change the values.
Once the required value is selected, press the ENTER button to confirm.
DMX ADDR
Used to set the desired DMX-address.
Press the MODE button until the desired function is
showing on the display.
Press the ENTER button: the values can be changed
Use DOWN and UP buttons to select the desired
DMX512 address. The last occupied DMX-address is
also shown: makes it easier to set the address of the
next unit in the chain.
Once the correct address shows on the display, press
the ENTER button to save it.
Note: on RDM-compatible controllers this option can
also be remotely set.
CH. MODE
Used to set the desired channel mode.
Press the MODE button until the desired function is
showing on the display.
Press the ENTER button: the values can be changed
Use DOWN and UP buttons to select the desired
mode:
CH:01
master dimmer
CH:02
strobe + master dimmer
Once the correct option shows on the display, press
the ENTER button to save it.
Remark: on RDM-compatible controllers this option can
also be remotely set.
SLAVE MODE
Used to set the projector as slave in a master/slave
setup.
Press the MODE button until SLAVE MODE is
showing on the display.
MASTER DIM
Used to set the master dimmer while used as master.
Press the MODE button until the desired function is showing on the display.
Press the ENTER button: the values can be changed
Use DOWN and UP buttons to select the desired level for the master dimmer. (please note that the last
selected static color will be used to set the value)
Once you have the desired level, press the ENTER button to save it.
Note: the setting of this option has NO effect while the projector is used as SLAVE or in DMX-mode.
DIMMER CURVE
Used to set the dimmer curve of the master dimmer.
Press the MODE button until the desired function is showing on the display.
Press the ENTER button: the values can be changed
Use DOWN and UP buttons to selected the desired curve:
BRITEQ
®
5/35
OPERATION MANUAL
BT-THEATRE 100EC MK2