installation
EXHAUST AND FRESH AIR INTAKE LOCATION
EXHAUST:
Base of unit to center of flue
Side of unit to center of flue
Center of unit to center of flue
FRESH AIR INTAKE:
Base of unit to center of intake
Side of unit to center of intake
Center of unit to center of intake
INSTALL VENT AT CLEARANCES SPECIFIED BY THE VENTING
MANUFACTURER.
3
7
/
"
16
(87mm)
10
7
/
8
(277mm)
Figure 26: Insert Inlet and Outlet Location.
OUTSIDE FRESH AIR CONNECTION
Outside fresh air is mandatory when installing this unit in airtight
homes and mobile homes.
A Fresh-air intake is strongly recommended for all installations.
Failure to install intake air may result in improper combustion as well as
the unit smoking during power failures.
When connecting to an outside fresh air source, do not use plastic or
combustible pipe. A 2" minimum (51 mm) ID (inside diameter) steel,
aluminum or copper pipe should be used. It is recommended, when you
are installing a fresh air system, to keep the number of bends in the pipe
to a minimum.
2" ID
(51 mm)
Figure 27: Outside Air Connection.
16 | Poêle et encastrable à granules Greenfire GF55 / GFI55 - Manuel technique
All manuals and user guides at all-guides.com
9-1/16" (229mm)
6-1/8" (156mm)
5-3/4" (146mm)
3-7/16" (87mm)
10-7/8" (277mm)
1" (25mm)
5
3
/
"
4
(146mm)
(229mm)
"
6
1
/
"
8
1"
(156mm)
(25mm)
Outside
Wall
Optional
Elbow
MASONRY FIREPLACE INSERT INSTALLATION
The GFI55 requires a surround faceplate and a pedestal. When installing
this unit, ensure that the pedestal is removed from the inside of the hopper
and installed on the bottom of the unit. Refer to "Installation of Pedestal
and Leveling Legs".
Adjust hopper height - refer to "Installing Hopper Cover and Adjusting Hop-
per Height" and assemble surround panel. See "Installation and Removal
on Control Panel in the Surround Panel" and "Assembly and Installation
of Insert Surround Panels" before starting installation.
A non-combustible hearth pad must cover combustible flooring underneath,
as well as 6" (150 mm) in front of the heater and 6" (150 mm) to the side
of the heater
1. Install the hearth pad, if required.
2. Lock the fireplace damper in the open position.
3. Install a positive flue connector at the fireplace damper.
4. Connect a tee or 90° degree elbow to the exhaust pipe.
5. This fireplace insert must be installed with a continuous chimney liner
of 3 or 4" diameter extending from the fireplace insert to the top of the
chimney. The liner must conform to type 3 requirements of CAN/ULC
S635. For lengths below 25' use 3" and increase to 4" if longer.
6. (Recommended) Install fresh air intake either through the back of the
fireplace or through the positive flue connector.
9
1
/
"
16
Rain Cap
Clean-out tee
If holes already exist
fresh-air intake can
be taken through the
back of the fireplace
or through the ash
Fresh-air intake
Steel Plate or Flashing
Masonry Fireplace
dump.
Figure 28: Installation of Fireplace Insert.
Damper Removed
or Fastened Open
Mantel (8" deep)
Min. 8" from
top of stove
Min. 6"
Floor
Protection
Combustible Floor

Publicité

loading

Produits Connexes pour Greenfire GF55

Ce manuel est également adapté pour:

Gfi55