UTILISATION
3 • Storing and transporting
the appliance
After use, stop your appliance by pressing
on the on/off pedal and unplug it
Stow the cable by pressing the automatic
cable rewind pedal
position, place the suction unit in the
parking position
carry and store your vacuum cleaner in the
(fi g.13)
park position
CARE AND CLEANING
IMPORTANT Always turn off and unplug
your appliance before maintenance or
cleaning.
1 • Changing the bag
The bag full indicator shows you when the
bag is full or saturated. If you notice that your
vacuum cleaner is less effi cient, select the
maximum power and hold the nozzle off the
fl oor. If the indicator remains red, replace the
bag. Open the cover on your vacuum cleaner
(fi g. 15)
. Remove the bag or wonderbag
and throw it away
new bag in the bag support guide using the
cardboard (fi g. 19) or a new wonderbag in
the support using its ring.
Position the bag and open it out inside the
compartment (fi g.20).
Make sure that the bag is in the correct
position before closing the cover.
IMPORTANT Never operate the vacuum
cleaner without a bag.
2 • Change the HEPA* fi lter
cassette (ref. ZR 0029 01)
IMPORTANT Replace the fi ltration system
once a year.
The HEPA fi lter cassette ref. ZR 0029 01 is
available from your dealer or Approved
*Depending on model:
this is either equipment specifi c to certain models or available as an optional accessory.
(fi g.8)
(fi g.9)
. In the upright
(fi g.10)
. You can then
. If your appliance is
(fi g. 16-17-18)
. Place a
equipped with the Compact System with
folding tubes:
Retract the telescopic tubes
press the «Push» button to open the tube
.
and fold it.
If
your
appliance
CLIP'N'STORE, attach your hose to the
accessory clip for easier storage
Service Centres.
Open the cover on your vacuum cleaner
(fi g. 15)
. Remove the bag or wonderbag
(fi g. 16)
, then remove the Hepa fi lter
(fi g. 21)
cartridge*
cassette in a waste bin
Fit the new Hepa* fi lter cassette (ref. ZR 0029 01)
in its compartment
Put the bag or wonderbag back in place.
Check that the Hepa* fi lter cassette is fi tted
correctly before re-closing the cover.
IMPORTANT Never operate the vacuum
cleaner without a Hepa fi lter cartridge.
Your appliance is equipped with a Hepa
fi lter cartridge presence safety system for
this (the cover will not close if a Hepa fi lter
cartridge has not been installed).
3 • Cleaning your vacuum
Clean the accessories of your appliance with
a soft damp cloth, then dry them. Do not use
abrasive or aggressive products.
9
(fi g. 11)
and
is
equipped
with
(fi g. 12)
and dispose of the
(fi g.22)
.
(fi g. 23)
.