Please read the product description prior to installing the unit.
Please check that the product is suitable for your application
without any restrictions.
If the operating instructions or the technical data are not
adhered to, personal injury and/or damage to property may
occur.
Please check in all applications that the product materials (see
Technical data) are compatible with the media to be mea-
sured.
For gaseous media the application is limited to max. 25 bar.
Function and features
The pressure sensor detects the system pressure and converts it into
an analog output signal.
• 4 ... 20 mA (PA3xxx) / 0 ... 10 V (PA9xxx)
Applications
Type of pressure: relative pressure
Order no.
PAxxx0
PAxxx1
PAxxx2
PAxxx3
PAxxx4
PAxxx6
PAxxx7
PAxxx9
PAxx60
Avoid static and dynamic overpressure exceeding the given over-
load pressure.
Even if the bursting pressure is exceeded only for a short time
the unit can be destroyed (danger of injuries)!
Safety instructions
Measuring range
0 ... 400 bar
0 ... 250 bar
0 ... 100 bar
0 ... 25 bar
0 ... 10 bar
0 ... 2.5 bar
0 ... 1 bar
-1 ... 0 bar
0 ... 600 bar
Permissible
overl. pressure
600 bar
400 bar
300 bar
100 bar
50 bar
20 bar
10 bar
10 bar
800 bar
Bursting pressure
1000 bar
850 bar
650 bar
350 bar
150 bar
50 bar
30 bar
30 bar
1200 bar