3.4

OUTSIDE AIR

IF ROOM AIR STARVATION OCCURS BECAUSE THE FRESH AIR INTAKE IS BLOCKED WITH ICE,
LEAVES, ETC., OR BECAUSE THE APPLIANCE DOOR WAS LEFT OPEN, OR DUE TO A STRONG
EXHAUST FAN OPERATING ETC., DANGEROUS FUMES AND SMOKE FROM THE OPERATING APPLI-
The following are signs that a fresh air kit may be required:
When there is combustion present: Wood burns poorly, smoke spills, back-draft takes place and your
chimney does not draw steadily.
In the winter there is too much condensation on the windows.
Opening a window seems to alleviate the above symptoms.
A ventilation system is installed in the house.
Other devices are present that exhaust house air.
The house has tight fi tting windows and/or is equipped with a well-sealed vapour barrier.
If possible connect the air intake at the pedestal's back or bottom to the outside with a 4 inch diameter fresh air
kit available at your authorized dealer / distributor.
WARNING
!
ANCE COULD BE DRAWN INTO THE ROOM.
13 3/8"
340mm
11 11/16"
297mm
9
EN
W415-1473 / 04.22.15