3. INSTALLATION / WALL FITTING
3.1. Carefully read the Safety warnings before starting to install the appliance.
3.2. Make sure that your power supply corresponds to the details on the specifi cations plate.
3.3. The appliance must be fi tted to the wall, respecting the minimum distances as shown in Fig. 2.
3.4. Installing with the moveable support
• Using the moving support (Fig. 1, J) as a template, mark the 4 holes in the wall. Use a spirit
level to ensure the support is completely horizontal.
• Then drill the 4 holes in the wall using an 8 mm diameter drill. Insert the four bolts with
metal wall plugs and using the 4 nuts (Fig. 1, K), secure the assembly to the wall. Use the
spanner provided (Fig. 1, I).
• Fit the appliance and the support and affi x with the rear screw (Fig. 3, A). When the
appliance is facing in the desired direction, make sure it does not move (Fig. 3, B).
3.5. IMPORTANT FOR FRANCE:
• Electrical power connection must be made by cutting off the supplied plug and using an
adequate terminal, as shown below.
Mains supply
• In damp areas or outdoor installations, the connection terminal should be installed at least
25 cm above fl oor level. Make sure the cable does not touch the ground.
4. USE
4.1. You can switch the device on or off (Fig.5.1) using the pull switch.
There are 3 control modes:
4.2. MANUAL
: lamps can be switched on or off using the ON/OFF button on the left (Fig.5.
2).
4.3. REMOTE CONTROL: The remote control can be used to switch the lamps on or off at a
distance (Fig. 5. 3).
4.4. AUTOMATIC
sensor detects a movement within its area of infl uence (Fig. 4) it will turn on the lamp(s).
If after 30 seconds, no movement is detected, the sensor will stop the lamps automatically.
ATTENTION: when you select the automatic operation mode, the manual operation and
remote control mode are inactive.
Live= Brown
Earth= Yellow-Green
Neutral= Blue
: Activating the PIR (Fig. 5. 4), it will control the device automatically. When
13
Device cable