This dehumidifier has been designed, manufactured and distributed by according to safety and
-The Dehumidifier has been designed and manufactured in conformity to all following European Norms
electro-magnetic compatibility to European Norms and Regulations:
and Regulations:
MACHINES NORMS (2006/42/CE - 17.05.2006) ;
-MACHINES NORMS (D.P.R., NR. 459 - 24th July 1996)
SECURITY REGULATIONS FOR LOW TENSION APPLIANCES 2006/95/CE - 12.12.2006;
-SECURITY REGULATIONS FOR LOW TENSION APPLIANCES
ELECTROMAGNETIC COMPATIBILITY (EMC) – 2004/108/CE – 15.12.2004.
(Law n. 791 - 18
Oct. 1977 and subsequent Law D.L. n. 626 - 25th Nov. 1996);
th
It is hereby certified that this Dehumidifier conform to the:
-ELECTROMAGNETIC COMPATIBILITY (EMC) - Law D.L. n. 476 - 4th Dec. 1992 and subsequent
IEC Regulations CEI-EN 60335-2-40, CEI-EN 55014-1, 55014-2.
The machine is built according to RoHS European Norms: 2011/65/UE year 2011 and CEI-EN
D.L. 615 - 12th Nov. 1996).
50581.
It is hereby certified that the dehumidifiers conform to the Regulations: CEI EN 60335-2-40, CEI EN
55014-1, CEI EN 55104-2, CEI EN 61000-3-2 and CEI EN 61000-3-3.
The control panel is placed on top of front side of the dehumidifier,
just over the air outlet grille.
It has elliptic form, four display lights and a speed controlling knob.
Over each signalling light there are following scripts:
• Green light 'FULL' the machine will stop when this light is 'on' because water tank is full.
Red Light 'POWER': machine plug is correctly inserted into power main line socket.
• Red Light 'RUNNING: when this line is 'on', it means that dehumidifier is running; in fact, if the light'
PAUSE' and 'FULL' are off, the compressor should be in function.
• Red light 'PAUSE' :means that the compressor is ready to start; this light will be on every time this
machine is started and after every defrosting operation which takes place periodically: the pause will
last 5 minutes.
• The Humidity Controlling Knob: it permits to change the degree of, relative humidity of the room; th4e
numbers mean the different performance required from the dehumidifier to obtain the desired humi-
dity level. Therefor, the higher is the number, the lower is the humidity: The humidity values advised
are obtained with speed set between 3 and 5 to which corresponds a 60% relative humidity.
• The indicator 'CONT.' (continuous): means that the dehumidifier will continue to function independently
from the relative humidity.
• The Indicator 'OFF', means that the humidostat is not activated and therefore the machine is not run-
ning: don't forget, however, that electric power is in the machine till its plug is not removed from the
socket of the electric main line.