rubber hose holder using first a 3-4 mm dia. drill and then an 8 mm dia. drill. For the connection, it should
possibly be used a silicon pipe having 14 mm internal diameter. On the bottom of the machine, just facing
the rubber hose holder there is a hole for the passage of the drain pipe
5. PERIODICAL MAINTENANCE
The only required periodical maintenance is the cleaning of the filter once every month, or more often
(even every two weeks) if the room is very dusty or the dehumidifier is working for many hours every day.
The cleaning must be done by placing the fitter under a water jet with the drilled panel facing the floor
so that the water jet may push the filter towards the drilled panel.
Note: You can require spare fitters from your dealer's service.
HUMIDITY CONDENSED IN 24 HOURS IN DIFFERENT CONDITIONS
model
20°C,60%R.H. 20°C,80%R.H. 25°C,60%R.H. 25°C,80%R.H. 27°C,65%R.H. 30°C,80%R.H. 32°C,90%R.H.
200
4 lit.
300
5 lit.
400
6 lit.
Power
model
supply
V/n/Hz
200
230/1/50
300
230/1/50
400
230/1/50
note: The average power consumption has benn calculated in 20°C - 60% R.H.. room
FILTER CLEANING
6. TECHNICAL DATA
in relation to the room temperature and r. humidity
5,5 lit.
5,5 lit.
7 lit.
7 lit.
8,5 lit.
8,5 lit.
power
functioning
functioning
con-
relative
temperature
sumption
humidity
range °C
W (*)
range.%
200
6-35 35-100 300
250
6-35 35-100 300
330
6-35 35-100 380
8 lit.
7,5 lit.
10,5 lit.
10 lit.
14,5 lit.
14 lit.
air
Tank
room
volume
capacity
volume
mc/h
litri
(indic.) mc
5,5
200
5,5
300
5,5
400
10
11 lit.
14lit.
15 lit.
19 lit.
19 lit.
24 lit.
size
ecological
Weight
LxPxH
refrigerant
Kg
cm
R134a
21
35x32x70
R134a
22
35x32x70
R134a
23
35x32x70