TEST AND ADJUSTMENT
1. Turn on the circuit breaker and light switch.
NOTE: Sensor has a 1
before it will detect motion. When first turned
on, wait 1
/
minutes.
1
2
2. Turn the RANGE control to the medium position
(halfway between MIN and MAX) and the ON-TIME
control to the TEST position.
ON-TIME
10 5 1 TEST
Bottom of Sensor
Avoid aiming the control at:
• Objects that change temperature rapidly, such as
heating vents and air conditioners. These heat
sources could cause false triggering.
• Areas where pets or traffic may trigger the control.
• Nearby large, light-colored objects reflecting light
may trigger the shut-off feature. Do not point other
lights at the sensor.
8 ft.
(2.4 m)
70 ft.
(21 m)
Maximum Range
/
minute warm up period
1
2
RANGE
MIN
MAX
180°
Maximum
Coverage Angle
NOTE: If fixture is mounted higher than 8 ft. (2.4 m), aim-
ing the sensor down will reduce coverage distance.
The detector is less sensitive to motion directly towards it.
Motion
Least Sensitive
3. Loosen the clamp screw in the
sensor ball joint and gently
rotate the sensor.
4. Walk through the coverage
area noting where you are
when the lights turn on (also,
the LED will flash several times
when motion is detected). Move
the sensor head up, down, or
sideways to change the cover-
age area. Keep the sensor at
least 1" (25 mm) away from
the bulbs.
5. Adjust the RANGE as needed.
RANGE set too high may
increase false triggering.
6. Secure the sensor head by
tightening the clamp screw.
Do not overtighten the screw.
7. Set the amount of ON-TIME you want the lights to
stay on after motion is detected (1, 5, or 10 minutes).
NOTE: It is recommended to use the 10 minute
ON-TIME setting when using CFL bulbs.
IMPORTANT: Do not leave ON-TIME switch in the
TEST position. The frequent ON/OFF cycling of the
bulb will reduce its life.
WARNING: Risk of fire. Do not aim the bulbs
at a combustible surface within 3 ft. (1 m).
4
Motion
Sensor
Most Sensitive
Clamp
Screw
Ball
Joint
Aim Sensor
Down for Short
Coverage
Aim Sensor
Higher for Long
Coverage
204026-03