Faucet leaks from tub spout/showerhead:
SHUT OFF WATER SUPPLIES.
Replace seats and springs–Repair
Kit RP4993. Check condition of lower O-rings
and replace if necessary RP14414. See
Helpful Hints 1, 2, & 3.
If leak persists:
SHUT OFF WATER SUPPLIES.
Replace valve cartridge RP46074.
See Helpful Hints 1, 2, 3 & 5.
Unable to maintain constant
water temperature:
Replace valve cartridge RP46074 or follow
instructions in Helpful Hints 1, 2, 4 & 5.
Helpful Hints:
1. Before removing valve cartridge assembly
for any maintenance, be sure to note the
position of the rotational limit stop on the cap.
The valve cartridge assembly must always be
put back in the same position. BE SAFE! After
you have finished the installation, turn on
valve to make sure COLD WATER FLOWS
FIRST.
2. To remove valve cartridge from body, shut
off water supplies and remove handle and
bonnet nut. Do not pry the valve cartridge
out of the body with a screwdriver. Place
handle on stem and rotate counterclockwise
T60P Series Maintenance
approximately 1/4 turn after the stop has
been contacted. Lift valve cartridge out of
body.
3. To remove seats and springs, remove
valve cartridge. Separate cap assembly
from the housing assembly by rotating
the cap assembly counterclockwise 90
(degrees). Separate cap and housing
assemblies. Remove seats and springs and
replace. Place the largest diameter of the
spring into the seat pocket first and then
press the tapered end of the seal over the
spring. Reassemble valve cartridge and
replace in body following instructions given
in 1 above.
4. If the water in your area has lime,
rust, sand or other contaminants in it,
your pressure balance valve will require
periodic inspection. The frequency of the
inspection will depend on the amount of
contaminants in the water. To inspect valve
cartridge remove it and follow the steps
in note 1 above. Turn the valve to the
full mix position and shake the cartridge
vigorously. If there is a rattling sound, the
unit is functional and can be reinstalled
following instructions given in note 1 above.
If there is no rattle, replace valve cartridge
RP46074.
5. Push disc until fully seated. See page 5
for more details.
10
o
92782 Rev. A