DESCRIPTION MAP
1
Alarm button (external call) *
2
Local call button **
3
'Alarm activated' LED
4
'Communication established' LED
*External call placed on configured SOS number (option P030 on the DAU) – this is for
lone maintenance workers who need to place an emergency call
**Local intercom call within the LPBus system is for communication within the lift shaft
and/or to the controller cabinet
FUNCTIONALITY
Press and hold the yellow button (1) to initiate an external alarm call. Once activated
the LED (3) (yellow) will turn on.
Once the external call has been placed an additional local intercom connection will
be enabled to allow for communication with all connected audio modules and the
external receiver. The local intercom connection will automatically be disabled when
the external call is hung up.
Once external communication is established LED (4) will light up in green.
5
LPBus connector to other devices
6
LPBus connector to the emergency telephone
7
Device speaker
8
Device microphone
J6
3