During the first use, proceed to the filtration of 3 liters of water, in order to ensure the freshness and safety of
If the device has a water leak, unplug the power supply and contact customer service.
In case of unusual presence of noise, smell, smoke or any other unusual behavior, disconnect the power supply
Following installation, the device automatically enters the initialization phase for 120 seconds. During this
initialization phase, the filtering in progress symbol of the display interface lights up (see diagram 2).
After the initialisation starts, the device automatically enters the filtering phase. The filtering in progress
symbol on the display interface lights up during the filtering phase (see diagram 2).
In normal operation, the device analyzes the water quality of the intake tank (see diagram 1). If the water level
is lower than the indicated minimum level, the water intake tank must be refilled. The water refill symbol of
34
6
U S E
1.
the water intended for consumption.
2.
3.
and contact the customer service.
1
Initialization
2
Filtering
3
Filling
the display interface lights up (see diagram 2).