SPC10-POT-...
3
Fitting and installing the pneumatic components
Mount the SPC10 horizontally or vertically on a level surface
with the aid of the support brackets supplied. You will require at
least 3 screws (M4) here.
Compressed air / service unit
•
5 to 7 bar, dried, non-lubricated 5 µm filter element.
•
Max. deviation in compressed air at the MPYE-5-... +/- 1 bar.
•
Sufficient standard flow (reference value: twice the standard
flow of the valve).
•
Microfilter if slight oil mist cannot be avoided.
Proportional directional control valve (type MPYE-5-...)
•
This should be fitted and connected up symmetrically to the
centre of the drive. If fitted to moving parts, the MPYE-5-...
should be mounted at right angles to the direction of move-
ment.
•
Fit silencers with large rated flow (e.g. U-1/8), maximum
length of tubing 1 m.
Compressed air tubing and screw connectors
•
Tubing for valve drive must be symmetrical:
tubing length = drive length.
•
Dimensions corresponding to rated size of the service unit,
the proportional directional control valve and the drive.
•
If
connectors from the Quick Star series.
•
Do not use any restrictors in the supply tubing.
9912d
angled
connectors
cannot
be
avoided,
use
plug
13