1
x
2
3
1
3
2
-
+
Make sure that water cooler is disconnected.
1.
Using a screwdriver, unscrew the screw (1) located on the
side, right, at the top of the panel (see photo).
Lift the cover up (2), then out of the slot by pulling forward, by
down
2.
Remove the black cap from the tank.
3.
Fill the tank with water until the stainless steel coils im-
mersive. Put the cap back.
4.
Connect the agitator pump terminal at back of the cooler.
5.
Insert the drain tube (1), connect the tube (2) on water
supply, and connect the power cable (3).
All tubes are located at the cooler back.
6.
Turn on the water supply.
CAUTION :
tion. Verify inside the tank: a ice cover should progressively
form around the stainless steel coils.
However, if the ice cover is unusually thick, immediately lo-
wering the thermostat from 2 or 3 clicks anticlockwise(-).
Then wait that ice cover thinned
WAIT 2H
that the cooler starts refrigera-
22