Ch. 4 Advanced Functions
A Click the Finish button. A dialog box
appears, showing that installation is fin-
ished.
B Click the Finish button.
NOTE
If a dialog box appears, explaining that the com-
puter should be restarted, select the option for
restarting the computer, click the Finish button to
restart the computer, and then remove the CD-
ROM from the computer.
Serial (RS-232C) mode
After the PT-9600 is connected to a computer
using an RS-232C cable, the P-touch must be set
to Interface mode in order for it to be able to
communicate with the computer.
To enter/exit Interface mode
(RS-232C connection):
●
Hold down d and press 0.
1 2 3 4 5 6 7 8 9 A B C D E F K Q Q Q Q Q
R
R
G
INTERFACE
R
H
R
RS ONLINE
R
I
R
J
AUTO
1.10
Length
Margin
62
Q Q Q Q
Q Q Q Q
Q Q Q Q
Q Q Q Q
Q Q Q
HELSINKI
A
AUTO
Font
Width
Size
NOTE
☞
To exit Interface mode and return to the text,
hold down d and press 0.
☞
To go offline, press e.
☞
To go back online, press the space bar.
☞
Before using the USB connection, exit Interface
mode (hold down d and press 0.)
☞
The baud rate of the PT-9600 does not change
automatically. If a baud rate of 9600 bps can
be used, the P-touch can be left at its default
baud rate setting. If the baud rate of the P-
touch must be changed, refer to To change the
settings for the standard serial (RS-232C) inter-
face parameters: on page 63, and then change
the baud rate setting of the P-touch.
With an RS-232C connection, there are two dif-
ferent print data formats for the Interface mode:
standard and ESC/P.
NOTE
Before using the Interface mode, select the print
data format (standard or ESC/P).
1
Press e to go offline.
2
Hold down d and press 2.
3
Press j or k until INTERFACE MODE is dis-
played.
4
Press m or g until the desired setting is dis-
played.
5
Press n.
Standard Interface mode (Mode that
enables printing from P-touch Editor
using an original P-touch driver)
With the standard Interface mode, the PT-9600
starts printing automatically when it receives a
print command from the computer. If no data is
received for 5 seconds, the PT-9600 automati-
cally exits Interface mode.
In the standard Interface mode, various interface
parameters can be selected to specify how the
data is sent from the computer.