1English1
M KEY, and the digit on the far right of the M-01 display will begin to flash; use
(up) or
(down) to select the memory data set (up and down keys can be held down
for continuous increasing or decreasing. Press the M Key after selected, will leave the
select mode to stop flash.
HOW TO SET TRACE MODE (F), PEAK MODE (K) OR ANGLE MODE (A)
TRACE MODE (F) (preset as trace mode at time of first use)
After setting a value (assuming the value is 50N-m), the force applied by the wrench
will gradually increase from 0000. When force is applied, the displayed value will
change as the user applies different amounts of force; the reading will increase as force
increased, and decrease as force decreased. The reading will jump to 50 N-m when the
user releases his grip and lets up.
PEAK MODE (K)
After setting a value (assuming the value is 50N-m), the force applied by the wrench
will gradually increase from 0000. When force is applied, the displayed value will
change as the user applies different amounts of force; the reading is the final torque
value. After the display flashes 10 seconds (no actions or buttons will be effective at
this time), it will automatic back to the original setting data or press the C key to return
to the selected value, or apply force again and the measured torque value will rise from
0000.
ANGLE MODE (A)
After setting a degree (assuming is 50 ), the force applied by the wrench will gradually
increase from 0 . When force is applied, the displayed degree will change as the user
applies different amounts of force. It will cross-display the final degree and torque
value when user stops force the wrench, 10 seconds flashing (no actions or buttons will
be effective at this time), it will automatic back to the original setting data or press the
C key to return to the selected value, or apply force again and the measured angle
degree will rise from 0 .
MEASUREMENT RANGE SELECTION
Values can be freely selected as long as force is not being measured or memory
selection has not been performed. After completing torque measurement in either mode,
the selected value can be displayed.
(UP) /
(DOWN) SELECTION
Pressing the
(up) key once will cause the value on the far right to increase by one;
pressing the key continuously will cause the value to increase continuously. Pressing
the
(down) key once will cause the value on the far right to decrease by one.
LED & BUZZER
The green LED will come on and there will be a beep each time a key is pressed.
In the tracking mode, the two LEDs will be green and red. For example: when the set
torque value is 20N-m, the reading will begin to change from 0000 as soon as the user
begins to apply force. It approach the preset value 80% the green light will now begin
English
-10