Télécharger Imprimer la page
Airxcel RV Products 48000 Serie Mode D'emploi Et Utilisation
Airxcel RV Products 48000 Serie Mode D'emploi Et Utilisation

Airxcel RV Products 48000 Serie Mode D'emploi Et Utilisation

Climatiseur de toit
Masquer les pouces Voir aussi pour RV Products 48000 Serie:

Publicité

Les langues disponibles

Les langues disponibles

Liens rapides

RV Products Division
OPERATION AND MAINTENANCE INSTRUCTIONS
FOR 48000 SERIES
ROOF TOP AIR CONDITIONERS
AND
CEILING PLENUMS
MODE D'EMPLOI ET UTILISATION
DES CLIMATISEURS DE TOIT DES
SÉRIES 48000
PLÉNUM DE PLAFOND

Publicité

loading

Sommaire des Matières pour Airxcel RV Products 48000 Serie

  • Page 1 RV Products Division OPERATION AND MAINTENANCE INSTRUCTIONS FOR 48000 SERIES ROOF TOP AIR CONDITIONERS CEILING PLENUMS MODE D’EMPLOI ET UTILISATION DES CLIMATISEURS DE TOIT DES SÉRIES 48000 PLÉNUM DE PLAFOND...
  • Page 2 TABLE OF CONTENTS General Information ..........Standard Ceiling Plenum Control Panel .
  • Page 3 FIGURE 1 III. OPERATION For Cooling (Refer to Figure 1, page 3). Operation During Cooler Nights (Cooling Operation). Turn the selector switch to the “LOW COOL” or “HIGH COOL” position. It is important, when the outdoor temperature drops in the evening or during the night to below 75 degrees F., that the Rotate the thermostat (temperature control) to the thermostat (temperature control) be set at a midpoint between...
  • Page 4 III. Short Cycling temperature of the air entering the air conditioning unit drops below this setting a few degrees and When an air conditioner is in operation, its compressor automatically turns off when the temperature of the circulates refrigerant under high pressure. Once off, it will air entering the air conditioner rises a few degrees take two to three minutes for this high pressure to equalize.
  • Page 5 The Coleman-Mach RV air conditioner is designed to operate on 115 volt electrical power. If the compressor on the air conditioner fails to start, check with your Airxcel, Inc. Service Center to determine...
  • Page 6 An optional three year extended parts only contract is available at an additional cost of $89.95. To obtain Airxcel, Inc. support help may be accessed by e-mail at this optional three year parts contract, fill out the RVPSupport@Airxcel.com.
  • Page 7 This Extended Parts Contract must be purchased within 90 days of the original (first) retail purchase of the covered air conditioner. The consumer must establish these dates by copy of the sales receipt. During the term of this Extended Parts Contract, Airxcel, Inc. agrees to furnish without charge any replacement parts required for the covered air conditioner because of defects in material or workmanship.
  • Page 8 TABLE DES MATIÈRES Renseignements généraux ..........Panneau de contrôle de plenum de plafond standard .
  • Page 9 Aérateurs – les aérateurs se trouvent aux deux diriger la décharge d’air de l’appareil. extrémités du couvercle du plafond et servent à III. FONCTIONNEMENT Pour le refroidissement (se reporter aux figure 1, Le compresseur du climatiseur est incapable de démarrer page 3).
  • Page 10 Si des filtres de remplacement sont nécessaries, on peut se les longue durée que l’on peut nettoyer et réutiliser, et ils filtrent procurer de la plupart des centres de service autorisés Airxcel, entièrement l’air circulé lorsque le climatiseur est en marche.
  • Page 11 Toute correspondance écrite doit être envoyée à l’adresse l’achat initial. suivante: Pour tout renseignement à propos de votre Airxcel, Inc. climatiseur de Coleman-Mach, vous devez indiquer RV Products Division le nom du modèle, les numéros de série et la date P.O.
  • Page 12 RV Products Division Airxcel, Inc. RV Products Division P.O. Box 4020 Wichita, KS 67204 1976-523 (12-09) PP...