INSTALLATION INSTRUCTIONS
FOR
48000 SERIES
HEAT PUMP
INSTRUCTIONS D'INSTALLATION
SÉRIE 48000
POMPE THERMIQUE

Publicité

Chapitres

Table des Matières
loading

Sommaire des Matières pour Airxcel 48000 Série

  • Page 1 RV Products Division INSTALLATION INSTRUCTIONS 48000 SERIES HEAT PUMP INSTRUCTIONS D’INSTALLATION SÉRIE 48000 POMPE THERMIQUE...
  • Page 2: Table Des Matières

    OEM – Please make sure the Customer Envelope Package INQUIRIES ABOUT THE HEAT PUMP UNIT – Inquiries to accompanies the heat pump. your Airxcel representative or to Airxcel pertaining to product installation should contain both the model and serial numbers INSTALLER AND/OR DEALER – Please make sure the of the roof top heat pump.
  • Page 3: Heat Pump Sizing

    II. HEAT PUMP SIZING Heat pumps should be rated primarily by their ability to cool. be 60 to 65 degrees F. As long as this temperature difference The thermal measurement used for detecting a gain or loss of (15 to 20 degrees) is being maintained at the heat pump, the heat is the British Thermal Unit (BTU).
  • Page 4 If the heat pump is being installed subject to heavy lateral This heat pump is to be installed in accordance with loads, it is advisable to order a “Roughneck” gasket/bolt NFPA Standard 501C. package, part number 48207-3301 to maintain bolt tension, prevent lateral movement of the heat pump and guard against The roof top heat pump must be mounted as near bolt shear.
  • Page 5 7 DEGREE MAX. ABOVE LEVEL 7 DEGREE MAX. ABOVE OR BELOW LEVEL NOTE: IF UNIT IS INSTALLED UNLEVEL FRONT TO BACK, THE NOSE OR FRONT OF THE UNIT MUST BE UP. DO NOT INSTALL NOSE DOWN. ALLOWABLE OFFSET FOR ALL HEAT PUMPS WITH RECIPROCATING COMPRESSORS.
  • Page 6: Securing The Heat Pump To The Roof

    V. SECURING THE HEAT PUMP TO THE ROOF A mounting frame is supplied with the ceiling assembly. Proper tension has been achieved for each bolt when Follow the steps below to secure the heat pump to the roof. any portion of each gasket indicating tab has been Refer to Figure 5.
  • Page 7: Electrical Wiring

    ROUTING 115 VAC WIRING STRIP THE INDIVIDUAL WIRE LEAD ENDS FOR WIRE CONNECTION Following Airxcel’s high voltage wiring specifications and all (ABOUT 3/4” BARE WIRE). INSERT local and national electrical codes, route the roof top unit 115 THE SUPPLY WIRES INTO THE VAC supply wiring from its power source to the wirebox.
  • Page 8 Carefully uncarton the ceiling assembly. Controls The ceiling assembly shroud is curved to contour to a are factory installed in the ceiling assembly (except crowned ceiling. If installation is to a flat ceiling ceiling assemblies for applications with remote and gaps are present on the sides of the shroud, control box/thermostat).
  • Page 9 FIGURE 12 FIGURE 13 FIGURE 14...
  • Page 10: Completing The Installation (9000 Series)

    VIII. COMPLETING THE INSTALLATION (9000 SERIES) Make sure the non-allergenic filters are properly System Checkout – Airxcel manufactures a wide positioned in the ceiling grille. range of roof top heat pumps which incorporate different product operation features. To properly Install the ceiling grille by positioning on the bottom evaluate the performance of a newly installed heat of the shroud and engaging the two 1/4 turn fasteners.
  • Page 11: Renseignements Généraux

    Il devrait aussi avoir la possibilité d’acheter le (1) étiquette signalétique que vous pouvez voir dans les contrat de trios (3) ans de pièces de rechange de Airxcel. persiennes de carénage du côté compresseur de la pompe thermique de toit. Vous pouvez la voir sans retirer le carénage Pour plus d’information au sujet du contrat, veuillez consulter...
  • Page 12: Installation De L'appareil Sur Le Toit

    La plupart du temps, les pompes thermiques de toit sont Caravanes classiques ou mini-maisons – il faudrait choisir un installées sur les events de toit actuels. S’il n’y a pas d’évents emplacement près de la portière, un peu vers l’avant du centre de toit (ouvertures d’installation déjà...
  • Page 13: Fixer La Pompe Thermique Au Toit

    Airxcel. Protection du circuit – voir la plaque d’identification sur la partie supérieure de l’appareil. Spécifications de câblage haute tension pour un dispositif de protection contre les surtensions possédant l’intensité...
  • Page 14: Installation Du Montage De Plafond (Série 9000)

    DANGER SI VOUS UTILISEZ DES CÂBLES AUTRES QUE LES CÂBLES NON- EN UTILISANT DES CÂBLES À GAINE MÉTALLIQUES COMME NON-MÉTALLIQUE (ROMEX, ETC.), CONDUCTEURS D’ALIMENTATION, DÉNUDEZ LA GAINE POUR EXPOSER VOUS DEVEZ UTILISER LES PINCES DE 4 À 6 POUCES (10,16 À 15,24 CM) DES OU CONNECTEURS DE RÉDUCTION FILS D’ALIMENTATION.
  • Page 15: Fin De L'installation (Série 9000)

    D. Mettez la pompe thermique de toit en marche. installés dans la grille du plafond. E. Vérification du système – Airxcel fabrique une vaste B. Installez la grille du plafond en la plaçant au bas du gamme de pompes thermiques de toit qui incorpore carénage et en fermant les deux attaches de 1/4 de...
  • Page 16 RV Products Division Airxcel, Inc. RV Products Division P.O. Box 4020 Wichita, KS 67204 1976B521 (12-12) PP...