Fisher & Paykel HP24ILTX2 Guide D'utilisation page 16

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

WARNING!
Electrical wiring must be done by qualified person(s) in accordance with all applicable
codes and standards and the unit must be grounded.
Electrical connection
7
Run three wires, two for the power supply and one for the ground wire, from the
power connection box on the ventilation hood to a power connection point near
the installation.
Open the power connection box on the ventilation hood and secure the power
conductor with a cULus listed strain relief (not included).
Connect the power conductors to the conductors for the ventilation hood, black to
black and white to white.
Connect the grounding wire (green or bare) to the ground conductor (green) of the
ventilation hood power connection box.
Secure all the connections with cULus listed wire nuts.
Replace the power connection box cover.
Gray
4 speed
Black
3 speed
Red
2 speed
Blue
1 speed
Brown
(neutral)
INSTALLATION INSTRUCTIONS
EN
14

Publicité

Chapitres

Table des Matières
loading

Ce manuel est également adapté pour:

Hp36iltx2

Table des Matières