WARNING!
Electrical wiring must be done by qualified person(s) in accordance with all applicable
codes and standards and the unit must be grounded.
Electrical connection
5
Run three wires, two for the power supply and one for the ground wire, from the
●
●
power connection box on the ventilation hood to a power connection point near
the installation.
Open the power connection box on the ventilation hood and secure the power
●
●
conductor with a cULus listed strain relief (not included).
Connect the power conductors to the conductors for the ventilation hood, black to
●
●
black and white to white.
Connect the grounding wire (green or bare) to the ground conductor (green) of the
●
●
ventilation hood power connection box.
Secure all the connections with cULus listed wire nuts.
●
●
Replace the power connection box cover.
●
●
Gray
4 speed
Black
3 speed
Red
2 speed
Blue
1 speed
Brown
(neutral)
16
INSTALLATION INSTRUCTIONS
Black/Noir (L)
White/Blanc (N)
Green/Vert (E)
120V~60Hz
M
Black/Noir
Black/Noir
Bornier
Junction
Capacitor
Box
Green/Vert
White/Blanc Motor
Orange/Orange Motor