3. Install New Flash Tube
EN
Make sure the power switch is off and the power cord is disconnected from the
source. Locate the two flash tube pin sockets above the modeling lamp socket. Using
white cotton gloves or a clean cloth, push the pins of the flash tube into the sockets
FR
using firm, even pressure at the base of the flash tube. With needle-nose pliers, hook
the retention spring over the hook above the flash tube. Re-insert the modeling lamp
using white cotton gloves or a clean cloth. Re-install the reflector.
ES

Changing the Fuse

A 4A fuse is mounted at the bottom of the flash unit.
1. Turn off the flash light, and disconnect the power supply before changing the fuse.
Never replace with a fuse of a different type or rating. A spare 4A fuse is fitted in the
fuse holder
2. Use a small screwdriver to release fuse cover, remove the older fuse, place the new
fuse in the slot, and then replace the fuse holder.

Overheating Protection

After a long shooting session at high output, the recycling time of the flash will in-
crease automatically until the flash cools down to a safe level and will start working
normally again.

Flash Capacitor Preventative Maintenance

One of the most important components of an electronic flash is the capacitors. Fol-
lowing the preventative maintenance below will increase the life and the reliability
of your flash.
If the unit is left unused for a few months or predominantly used at low power set-
tings, it is recommended that the power be increased to maximum and the unit left
switched on (modeling lamp OFF) occasionally for at least 30 minutes to help pre-
serve the life of the capacitors.