USE AND MAINTENANCE MANUAL
CHAPTER 8

DISASSEMBLY AND DISPOSAL

DANGER - ELECTRIC SHOCK RISK
Before any intervention on the pump, disconnect the electrical mains. Ensure that the electrical power
supply cannot be restored inadvertently.
• Disconnect the pump electrically
from the system according to
safety standards
DANGER
Note the position of the filler hole, which is also used as a bleed point. Ensure that the liquid on outlet
cannot cause damage or physical injury.
• Loosen the filler cap to reduce
the pressure of the liquid
remaining between the two
valves
This product or any part of the latter must be disposed of in accordance with local standards using the public or
private waste collection authorities as required.
32
• Open the tap nearest to the
pump to decrease the system's
pressure
• Remove the drain cap from the
pump body to completely empty
the pump
• Before disassembly, close the
shutoff valves on the delivery
side, and if present also close the
shutoff valve on the suction side.